CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the transmission valve body assembly removal/installation are shown below.
| Replacement Part or Procedure | Necessary Procedures | Effects/Inoperative when not Performed | Link |
|---|---|---|---|
|
Drive learning |
|
PROCEDURE
AIR SUSPENSION CONTROL PROHIBITED (w/ Air Suspension)
REMOVE TRANSMISSION UNDER COVER
DRAIN TRANSMISSION FLUID
REMOVE TRANSMISSION OIL PAN SUB-ASSEMBLY
REMOVE OIL STRAINER ASSEMBLY
DISCONNECT TRANSMISSION WIRE
| *1 | Temperature Sensor |
| *2 | Lock Plate |
Remove the bolt and lock plate and disconnect the temperature sensor from the transmission valve body assembly.
Remove the O-ring from the temperature sensor.
Detach the wire harness clamp.
Disconnect the 7 connectors from the transmission valve body assembly.
REMOVE TRANSMISSION VALVE BODY ASSEMBLY
Remove the 15 bolts and transmission valve body assembly.
Remove the 3 gaskets from the transmission case.