Click here

DOOR LOCK SERVICE DATA

Click here
Click here
Table 1. Front Door Lock with Motor Assembly LH (w/o Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H23-8 (UL) - H23-9 (E) Held to unlock side Below 1 Ω
H23-8 (UL) - H23-9 (E) Neutral or held to unlock side 10 kΩ or higher
H23-7 (L) - H23-9 (E) Neutral or held to lock side 10 kΩ or higher
H23-7 (L) - H23-9 (E) Held to lock side Below 1 Ω
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H23-10 (LSSR) - H23-9 (E) Lock 10 kΩ or higher
H23-10 (LSSR) - H23-9 (E) Unlock Below 1 Ω
Table 2. Front Door Lock with Motor Assembly RH (w/o Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H6-7 (UL) - H6-6 (E) Held to unlock side Below 1 Ω
H6-7 (UL) - H6-6 (E) Neutral or held to unlock side 10 kΩ or higher
H6-8 (L) - H6-6 (E) Neutral or held to lock side 10 kΩ or higher
H6-8 (L) - H6-6 (E) Held to lock side Below 1 Ω
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H6-5 (LSSR) - H6-6 (E) Lock 10 kΩ or higher
H6-5 (LSSR) - H6-6 (E) Unlock Below 1 Ω
Table 3. Front Door Lock with Motor Assembly LH (w/ Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H23-8 (UL) - H23-9 (E) Held to unlock side Below 1 Ω
H23-8 (UL) - H23-9 (E) Neutral or held to unlock side 10 kΩ or higher
H23-7 (L) - H23-9 (E) Neutral or held to lock side 10 kΩ or higher
H23-7 (L) - H23-9 (E) Held to lock side Below 1 Ω
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H23-10 (LSSR) - H23-9 (E) Lock 10 kΩ or higher
H23-10 (LSSR) - H23-9 (E) Unlock Below 1 Ω
H23-6 (DLSR) - H23-5 (E) Unset 10 kΩ or higher
H23-6 (DLSR) - H23-5 (E) Set Below 1 Ω
Table 4. Front Door Lock with Motor Assembly RH (w/ Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H6-7 (UL) - H6-6 (E) Held to unlock side Below 1 Ω
H6-7 (UL) - H6-6 (E) Neutral or held to unlock side 10 kΩ or higher
H6-8 (L) - H6-6 (E) Neutral or held to lock side 10 kΩ or higher
H6-8 (L) - H6-6 (E) Held to lock side Below 1 Ω
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected H6-5 (LSSR) - H6-6 (E) Lock 10 kΩ or higher
H6-5 (LSSR) - H6-6 (E) Unlock Below 1 Ω
H6-9 (DLSR) - H6-10 (E) Unset 10 kΩ or higher
H6-9 (DLSR) - H6-10 (E) Set Below 1 Ω
Table 5. Rear Door Lock Assembly LH (w/o Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected K16-9 (LSSR) - K16-10 (E) Locked 10 kΩ or higher
K16-9 (LSSR) - K16-10 (E) Unlocked Below 1 Ω
Table 6. Rear Door Lock Assembly RH (w/o Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected K2-5 (LSSR) - K2-6 (E) Locked 10 kΩ or higher
K2-5 (LSSR) - K2-6 (E) Unlocked Below 1 Ω
Table 7. Rear Door Lock Assembly LH (w/ Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected K16-9 (LSSR) - K16-10 (E) Locked 10 kΩ or higher
K16-9 (LSSR) - K16-10 (E) Unlocked Below 1 Ω
K16-5 (DLSR) - K16-6 (E) Unset 10 kΩ or higher
K16-5 (DLSR) - K16-6 (E) Set Below 1 Ω
Table 8. Rear Door Lock Assembly RH (w/ Double Locking System)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected K2-5 (LSSR) - K2-6 (E) Locked 10 kΩ or higher
K2-5 (LSSR) - K2-6 (E) Unlocked Below 1 Ω
K2-9 (DLSR) - K2-10 (E) Unset 10 kΩ or higher
K2-9 (DLSR) - K2-10 (E) Set Below 1 Ω