OUTER MIRROR SWITCH INSPECTION

PROCEDURE


  1. INSPECT MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY

    B000P5OC01
    *a

    Component without harness connected

    (Multiplex Network Master Switch Assembly)


    1. Check the illumination.


      1. Apply auxiliary battery voltage to the connector and check the illumination conditions.

        OK
        Auxiliary Battery Connection Specified Condition

        Auxiliary battery positive (+) → 3 (ILL+)

        Auxiliary battery negative (-) → 13 (ILL-)

        Illuminates

        If the result is not as specified, replace the multiplex network master switch assembly.