PROCEDURE
INSPECT AIR CONDITIONER PRESSURE SENSOR
Check the wire harness.
Disconnect the A39 air conditioner pressure sensor connector.
Disconnect the P57 air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
| *b | Front view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the resistance is not as specified, repair the wire harness.
Reconnect the P57 air conditioning amplifier assembly connector.
Turn the power switch on (IG).
| *a | Front view of wire harness connector (to Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Connect the connector to the air conditioner pressure sensor.
Install a manifold gauge set.
Warm up the compressor.
Turn the A/C switch on.
Measure the voltage according to the value(s) in the table below.
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
*Value when sensor power source voltage is 5 V
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
- | - |
If the voltage is not as specified, replace the air conditioner pressure sensor.