REFRIGERANT LINE INSTALLATION

PROCEDURE


  1. INSTALL PIPING CLAMP


    1. Remove the vinyl tape from the cooler refrigerant liquid pipe A and liquid tube sub-assembly A.

    2. Sufficiently apply compressor oil to 2 new O-rings and the fitting surfaces of the cooler refrigerant liquid pipe A.

      Compressor Oil
      ND-OIL 11 or equivalent

      Note

      Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in leakage of electric power.

    3. Install the 2 O-rings to the liquid tube sub-assembly A.

      Note

      Keep the O-rings and O-ring fitting surfaces free of foreign matter.

    4. Install the cooler refrigerant liquid pipe A to the liquid tube sub-assembly A.

      Note


      • Make sure not to cut the O-ring while installing it. (Cut O-rings cannot be installed)

      • Check that the assemblies are securely engaged.

    5. B000OJSC02
      *a Correct
      *b Incorrect
      *c No Gap
      *d Gap

      Install the piping clamp to the cooler refrigerant liquid pipe A.

      Note

      Make sure that the piping clamp is engaged securely with no gap.

  2. INSTALL HEADLIGHT ASSEMBLY LH

    Click here

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

    for HFC-134a(R134a):

    Click here

    for HFO-1234yf(R1234yf):

    Click here

  4. WARM UP COMPRESSOR

    for HFC-134a(R134a):

    Click here

    for HFO-1234yf(R1234yf):

    Click here

  5. INSPECT FOR REFRIGERANT LEAK

    for HFC-134a(R134a):

    Click here

    for HFO-1234yf(R1234yf):

    Click here