AIR CONDITIONING SYSTEM No Heating at All

DESCRIPTION

If warm air is not discharged (airflow volume control is normal), the following malfunctions are possible.

Malfunction Status Factor

  • No heating at all (airflow volume control is normal)

  • Air outlet temperature does not increase (arflow volume control is normal)


  • Low engine coolant temperature

  • A/M damper and link operation (jamming)

  • Warm-up Control

  • Heater core closed waterway

  • Heater accessory assembly

PROCEDURE


  1. READ VALUE USING GTS (COOLANT TEMPERATURE)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Engine / Data List.

    5. Read the Data List according to the display on the GTS.


      Powertrain > Engine
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Coolant Temperature Engine coolant temperature Min.: -40°C (-40°F), Max.: 140°C (284°F) 75 to 100°C (167 to 212°F): After warming up

      This is the engine coolant temperature.

      Tech Tips


      • After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

      • After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

      • If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

      • Check if the engine overheats if the value indicated is higher than 135°C (275°F).


      Powertrain > Engine > Data List
      Tester Display
      Coolant Temperature
      OK
      The value of the display does not change frequently.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. PERFORM ACTIVE TEST USING GTS (SERVO PULSE)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Air Mix Servo Targ Pulse(D)

        for LHD:

      • No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation


        for RHD:

      • No. 4 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation

      Min.: 128

      Max.: 383

      Operates between 186 and 258 pulses
      Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation

      Min.: 128

      Max.: 383

      Operates between 154 and 258 pulses

      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(D)

      Body Electrical > Air Conditioner > Active Test
      Tester Display
      Air Mix Servo Targ Pulse(P)
      OK
      Damper servo motor is operated.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT HEATER ACCESSORY ASSEMBLY


    1. Remove the heater accessory assembly.

      Click here

    2. Inspect the heater accessory assembly.

      Click here

      Result
      Proceed to
      OK
      NG

    OK
    NG