| DTC Code | DTC Name |
|---|---|
| B1497 | Communication Malfunction (Bus Ic) |
DESCRIPTION
The air conditioning harness assembly connects the air conditioning amplifier assembly and the servo motors. The air conditioning amplifier assembly supplies power and sends operation instructions to each servo motor through the air conditioning harness assembly. Each servo motor sends damper position information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1497 | Communication Malfunction (Bus Ic) |
|
|
Memorized |
WIRING DIAGRAM
Figure 1. for LHD:
Figure 2. for RHD:
PROCEDURE
PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 186 and 258 pulses |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation | Min.: 128 Max.: 383 |
Operates between 154 and 258 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
Operates between 206 and 238 pulses |
| Cool A/M Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 154 and 258 pulses |
| Cool A/M Servo Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation | Min.: 128 Max.: 383 |
Operates between 254 and 326 pulses |
| Face A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 258 and 364 pulses |
| Foot A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 256 and 365 pulses |
| DEF A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 164 and 270 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
| Tester Display |
|---|
| Cool A/M Servo Pulse(D) |
| Tester Display |
|---|
| Cool A/M Servo Pulse(P) |
| Tester Display |
|---|
| Face A/O Servo Pulse(D) |
| Tester Display |
|---|
| Foot A/O Servo Pulse(D) |
| Tester Display |
|---|
| DEF A/O Servo Pulse(D) |
| OK |
|---|
| Damper servo motor is operated. |
Check the operation by referring to the table below.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
REPLACE AIR CONDITIONING HARNESS ASSEMBLY Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| A |
|
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (POWER SOURCE CIRCUIT)
Disconnect the air conditioning amplifier assembly connector.
| *a | Component without harness connected (Air Conditioning Amplifier Assembly) |
- | - |
Measure the reisistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Tester Connection | 2 (BUS G) - 3 (BUS) |
| Tool Setting | 2 V/DIV., 20 μs/DIV. |
| Condition | Power switch on (IG) |
| OK |
|---|
| The waveform displays properly. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| NG |
|
REPLACE AIR CONDITIONING HARNESS ASSEMBLY Click here |