PROCEDURE
INSPECT FRONT HEIGHT CONTROL SENSOR SUB-ASSEMBLY
Connect 3 dry cell batteries (1.5 V) in series.
Note
Do not use rechargeable batteries as they may not output a voltage of 1.5 V.
| *A | for LH side | *B | for RH side |
| *a | Component without harness connected (Front Height Control Sensor Sub-assembly) |
*b | Low |
| *c | Standard Position | *d | High |
| *e | 30° | *f | 30° |
| *g | 8.7° | - | - |
Connect a positive (+) lead from the batteries to terminal 3 (SHB) and a negative (-) lead to terminal 1 (SHG).
Measure the voltage between terminals 2 (SHFL, SHFR) and 1 (SHG) while slowly moving the link up and down.
| Standard Voltage | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| for LH side | ||||||||||
|
||||||||||
| for RH side | ||||||||||
|
If the result is not as specified, replace the front height control sensor sub-assembly.