PROCEDURE
INSPECT CHARCOAL CANISTER ASSEMBLY
Slide the clamp and disconnect the purge line hose from the charcoal canister assembly.
Visually check the charcoal canister assembly for cracks or damage.
If cracks or damage is found, replace the charcoal canister assembly.
| *a | Vent Line Port |
| *b | Purge Line Port |
| *c | Air Line Port |
|
Air |
Check the charcoal canister assembly operation.
With the purge line port closed, blow air at 5 kPa (0.1 kgf/cm2, 0.7 psi) into the vent line port and check that air flows from the air line port.
| *a | Vent Line Port |
| *b | Purge Line Port |
| *c | Air Line Port |
|
Air |
With the vent line port closed, blow air at 5 kPa (0.1 kgf/cm2, 0.7 psi) into the air line port and check that air flows from the purge line port.
If the result is not as specified, replace the charcoal canister assembly.
Check for air leaks.
| *a | Air Line Port |
| *b | Purge Line Port |
| *c | Vent Line Port |
| *d | Pressure Gauge |
Connect a pressure gauge to the vent line port of the charcoal canister assembly.
With the purge line port and air line port closed, apply pressurized air at 19.6 kPa (0.2 kgf/cm2, 2.8 psi) into the vent line port, and then confirm that pressure is retained for 1 minute.
If the result is not as specified, replace the charcoal canister assembly.
Connect the purge line hose to the charcoal canister assembly, and slide the clamp to secure hose.
INSPECT FUEL OUTLET VALVE ASSEMBLY
Visually check the fuel outlet valve assembly for cracks or damage.
If cracks or damage is found, replace the fuel outlet valve assembly.
Check the fuel outlet valve assembly operation.
Connect a positive (+) lead from the battery to terminal 5 and a negative (-) lead to terminal 1.
Check that a clicking sound is heard from the fuel outlet valve assembly.
If the result is not as specified, replace the fuel outlet valve assembly.
| *a | Fuel Vent Hose Sub-assembly |
| *b | Air Line Port |
| *c | Connector |
|
Air |
With the connector closed, blow air at 5 kPa (0.1 kgf/cm2, 0.7 psi) into the air line port and check that air flows from the fuel vent hose sub-assembly.
If the result is not as specified, replace the fuel outlet valve assembly.
Check for air leaks.
Connect the fuel outlet valve assembly to the charcoal canister assembly.
| *a | Purge Line Port |
| *b | Air Line Port |
| *c | Vent Line Port |
| *d | Connector |
| *e | Pressure Gauge |
Connect a pressure gauge to the vent port of the charcoal canister assembly.
With the purge line port, air line port and connector closed, apply pressurized air at 19.6 kPa (0.2 kgf/cm2, 2.8 psi) into the vent line port, and then confirm that pressure is retained for 1 minute.
If the result is not as specified, replace the fuel outlet valve assembly.
Disconnect the fuel outlet valve assembly to the charcoal canister assembly.