TELEMATICS SYSTEM(for G-BOOK) TERMINALS OF ECU


  1. TELEPHONE TRANSCEIVER ASSEMBLY

    B004A0AC01
    *a Connect to telephone antenna connector - -
    Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
    P134-1 (+B) - P134-4 (E) LA-P - W-B Power source (+B) Power switch off 11 to 14 V
    P134-2 (SPI+) - P134-4 (E) L - W-B Sound signal Audio system playing A waveform synchronized with sound is output
    P134-3 (SPI-) - P134-4 (E) P - W-B Sound signal Audio system playing A waveform synchronized with sound is output
    P134-4 (E) - Body ground W-B - Body ground Ground Always Below 1 Ω
    P134-5 (SPO+) - P134-4 (E) L - W-B Sound signal Emergency call mode A waveform synchronized with the received voice is output
    P134-6 (SPO-) - P134-4 (E) P - W-B Sound signal Emergency call mode A waveform synchronized with the received voice is output
    P134-7 (IG2) - P134-4 (E) G - W-B Power source (IG) Power switch on (IG) 11 to 14 V
    Power switch off Below 1 V
    P134-8 (ACC) - P134-4 (E) BE - W-B Power source (ACC) Power switch on (ACC) 11 to 14 V
    Power switch off Below 1 V
    P134-9 (SLED) - P134-4 (E) SB - W-B Emergency call switch illumination power supply Power switch on (ACC) 5 to 8 V
    Power switch off Below 1 V
    P134-11 (IND1) - P134-4 (E) BR - W-B Emergency call switch red indicator illumination signal For 5 seconds after turning the power switch on (ACC) 1 to 8.5 V
    Power switch off Below 1 V
    P134-12 (IND2) - P134-4 (E) P - W-B Emergency call switch green indicator illumination signal For 5 seconds after turning the power switch on (ACC) 1 to 8.5 V
    Power switch off Below 1 V
    P134-13 (BBI-) L Mayday battery (Back-up Battery) power supply - -
    P134-15 (CANP) W CAN communication signal - -
    P134-16 (CANN) LG CAN communication signal - -
    P134-17 (MUTE) - P134-4 (E) V - W-B MUTE Signal Audio system playing 3.5 V or higher
    Emergency call mode Below 1 V
    P134-18 (MCO+) - P134-4 (E) W - W-B Microphone voice signal

    Refer to "Microphone Check"

    Click here

    -
    P134-19 (MCO-) - P134-4 (E) B - W-B Microphone voice signal

    Refer to "Microphone Check"

    Click here

    -
    P134-20 (CTR1) B Mayday battery (Back-up Battery) control line - -
    P134-21 (CTR2) W Mayday battery (Back-up Battery) control line - -
    P134-24 (GSW) - P134-4 (E) R - W-B Airbag deployment signal Power switch on (IG)

    Pulse generation

    (Refer to waveform 1)

    P134-26 (SIG-) - P134-4 (E) V - W-B Ground Always Below 1 Ω
    P134-27 (SIG1) - P134-26 (SIG-) Y - G Emergency call switch button condition signal Emergency call switch not pressed 1.3 to 1.9 V
    Emergency call switch pressed 0.5 to 0.8 V
    P134-30 (BBI+) P Mayday battery (Back-up Battery) power supply - -
    P134-32 (SGND) - P134-4 (E) Shielded - W-B Shield ground Always Below 1 Ω
    P134-33 (MCVD) - P134-4 (E) R - W-B Telephone microphone assembly power supply Power switch on (ACC) 4 to 6 V
    Power switch off Below 1 V
    P134-34 (MCI+) - P134-4 (E) W - W-B Microphone voice signal

    Refer to "Microphone Check"

    Click here

    -
    P134-35 (MCI-) - P134-4 (E) B - W-B Microphone voice signal

    Refer to "Microphone Check"

    Click here

    -
    P136-4 (USB-) GR USB communication line - -
    P136-5 (USB+) GR USB communication line - -
    P136-6 (USBS) - Body ground GR - Body ground Shield ground Always Below 1 Ω
    P136-1 (USBG) - Body ground W - Body ground Shield ground Always Below 1 Ω
    P136-2 (VOT+) - P134-4 (E) B - W-B Sent voice signal Calling while using the operator service A waveform synchronized with the sent voice is output
    P136-3 (USBV) - P134-4 (E) W - W-B Signal for connection check of DCM and radio receiver assembly Power switch on (ACC) 3.0 to 5.25 V
    Power switch off Below 1 V
    P136-7 (VOT-) - P134-4 (E) B - W-B Sent voice signal Calling while using the operator service A waveform synchronized with the sent voice is output
    P136-8 (VOR-) - P134-4 (E) B - W-B Receive voice signal Receiving a call while using the operator service A waveform synchronized with the received voice is output
    P136-9 (VOR+) - P134-4 (E) B - W-B Receive voice signal Receiving a call while using the operator service A waveform synchronized with the received voice is output

    1. Reference (Oscilloscope waveform):


      1. B004BXQE01

        Waveform 1

        Item Condition
        Tester Connection P134-24 (GSW) - P134-4 (E)
        Tool Setting 5.0 V/DIV., 20 ms./DIV.
        Vehicle Condition Power switch on (IG)
  2. RADIO RECEIVER ASSEMBLY

    Click here

  3. NAVIGATION ECU

    Click here