AIR CLEANER FILTER ELEMENT REMOVAL

PROCEDURE


  1. REMOVE RADIATOR SUPPORT TO FRAME SEAL RH

    Click here

  2. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


    1. B000TNN

      Disconnect the 2 clamp hooks.

    2. Remove the air cleaner filter element sub-assembly from the air cleaner assembly.

      Note

      Do not allow foreign matter to enter the air cleaner assembly.

  3. INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Tech Tips

    This procedure is only performed when the air cleaner filter element sub-assembly will be reused.


    1. Check whether the air cleaner filter element sub-assembly is dirty or clogged.

    2. B000TNBC01
      *a Air Cleaner Filter Element Sub-assembly Intake Downstream Side

      If the air cleaner filter element sub-assembly is dirty or has foreign matter adhered to it, clean the air cleaner filter element sub-assembly with compressed air.

      Note

      When cleaning the air cleaner filter element sub-assembly, blow the compressed air from the intake downstream side.

      Tech Tips

      If the air cleaner filter element sub-assembly is still extremely dirty after cleaning it, replace the air cleaner filter element sub-assembly with a new one.