DESCRIPTION
If warm air is not discharged (airflow volume control is normal), the following malfunctions are possible.
| Malfunction Status | Factor |
|---|---|
|
|
PROCEDURE
READ VALUE USING GTS (COOLRANT TEMPERATURE)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. Tech Tips
|
| Tester Display |
|---|
| Coolant Temperature |
| OK |
|---|
| The value of the display does not change frequently. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING SYSTEM Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 186 and 258 pulses |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-asembly (front passenger side upper air mix) operation | Min.: 128 Max.: 383 |
Operates between 154 and 258 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-asembly operation | Min.: 128 Max.: 383 |
Operates between 130 and 162 pulses |
| Cool A/M Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 154 and 258 pulses |
| Cool A/M Servo Pulse(P) | No. 2 air conditioning radiator damper servo sub-asembly (front passenger side lower air mix) operation | Min.: 128 Max.: 383 |
Operates between 254 and 326 pulses |
| Face A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 258 and 364 pulses |
| Foot A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 256 and 365 pulses |
| DEF A/O Servo Pulse(D) |
for LHD:
for RHD: |
Min.: 128 Max.: 383 |
Operates between 164 and 270 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
| Tester Display |
|---|
| Air Inlet Damper Targ Pulse |
| Tester Display |
|---|
| Cool A/M Servo Pulse(D) |
| Tester Display |
|---|
| Cool A/M Servo Pulse(P) |
| Tester Display |
|---|
| Face A/O Servo Pulse(D) |
| Tester Display |
|---|
| Foot A/O Servo Pulse(D) |
| Tester Display |
|---|
| DEF A/O Servo Pulse(D) |
| OK |
|---|
| Damper servo motor is operated. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY Click here |
| NG |
|
GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION) Click here |