REFRIGERANT SHORTAGE CHECK USING GTS
Connect the GTS to the DLC3.
Engine is started.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
According to the display on the GTS, perform the refrigerant shortage check when the following conditions are met.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
Refer to the GTS operator's manual for further details.
A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant shortage check using the GTS.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| Refrigerant shortage | Insufficient or leakage |
|
| Refrigerant correct | Correct | - |