CLOCK INSPECTION

PROCEDURE


  1. INSPECT CLOCK ASSEMBLY


    1. B000YSUC02
      *a

      Component without harness connected

      (Clock Assembly)

      Check illumination.


      1. Apply battery voltage to the clock assembly and check that it illuminates.

        OK
        Condition Specified Condition

        Battery positive (+) → Terminal 1 (B)

        Battery positive (+) → Terminal 2 (ACC)

        Battery negative (-) → Terminal 7 (E)

        Illuminates

        If the result is not as specified, replace the clock assembly.