NAVIGATION SYSTEM Vehicle Speed Signal Circuit between Stereo Component Amplifier and Combination Meter

DESCRIPTION

The stereo component amplifier assembly receives a vehicle speed signal from the combination meter assembly to control the ASL function.

Tech Tips


  • A voltage of 12 V or 5 V is output from each ECU and then input to the combination meter assembly. The signal is changed to a pulse signal at the transistor in the combination meter assembly. Each ECU controls its respective systems based on this pulse signal.

  • If a short occurs in any of the ECUs or in the wire harness connected to an ECU, all systems in the diagram below will not operate normally.

WIRING DIAGRAM

B000U9QE02
*1 to Other Systems
*2 Combination Meter Assembly
*3 Stereo Component Amplifier Assembly

PROCEDURE


  1. CHECK COMBINATION METER ASSEMBLY (OUTPUT WAVEFORM)


    1. B000UVGC76
      *a

      Component with harness connected

      (Combination Meter Assembly)

      Check the output waveform.


      1. Remove the combination meter assembly with the connector still connected.

      2. Connect an oscilloscope to terminal P25-19 (+S) and body ground.

      3. Turn the engine switch on (IG).

      4. Turn a wheel slowly.

      5. Check the signal waveform according to the condition(s) in the table below.

        Item Condition
        Measurement terminal P25-19 (+S) - Body ground
        Tool setting 5 V/DIV., 20 ms./DIV.
        Vehicle condition Wheel being rotated
        OK
        The waveform is similar to that shown in the illustration.

        Tech Tips

        When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - COMBINATION METER ASSEMBLY)


    1. Disconnect the X49 stereo component amplifier assembly connector.

    2. Disconnect the P25 combination meter assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      X49-17 (SPD) - P25-19 (+S) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG