PROCEDURE
INSPECT FAN AND GENERATOR V BELT
Tech Tips
Check only when reused.
Check the fan and generator V belt for wear, cracks or other signs of damage.
If any of the following defects is found, replace the fan and generator V belt.
The fan and generator V belt is cracked.
The fan and generator V belt is worn to the extent that the cords are exposed.
The fan and generator V belt has chunks missing from the ribs.
| *a | Correct |
| *b | Incorrect |
Check that the fan and generator V belt fits properly in the ribbed grooves.
Tech Tips
Check by hand to confirm that the fan and generator V belt has not slipped out of the grooves on the bottom of the pulley. If it has slipped out, replace the fan and generator V belt. Install a new fan and generator V belt correctly.
INSPECT V-RIBBED BELT TENSIONER ASSEMBLY
Check that nothing is caught in the V-ribbed belt tensioner assembly by turning it clockwise and counterclockwise.
If a malfunction exists, replace the V-ribbed belt tensioner assembly.