Data List
Note
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Sub Battery Module / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Sub Battery Module Low Voltage Count | This parameter indicates the number of times the sub-battery module has been determined as low voltage. | 0 to 255 | 0 to 255 |
|
| Backup Relay Low Voltage Count | This parameter indicates the number of times the backup relay has been determined as low voltage. | 0 to 255 | 0 to 255 |
|
| Sub Battery Module Voltage | This parameter indicates the voltage of the sub-battery. | 0 to 65.535 V | 11 to 15 V |
|
| Sub Battery Module Current | This parameter indicates the current of the sub-battery. | -300 to 300 A | -100 to 100 A |
|
| Sub Battery Module Temperature | This parameter indicates the temperature of the sub-battery. | -50 to 120°C (-58 to 248°F) | -30 to 75°C (-22 to 167°F) |
|
| Sub Battery Module State of Charge | This parameter indicates the capacity of the sub-battery. | 0 to 100% | 10 to 100% |
|
| Sub Battery Module State of Health | This parameter indicates the battery deterioration rate of the sub-battery module. | 0 to 100% | 24 to 100% |
|
| Sub Battery Module Internal Resistance | This parameter indicates the internal resistance value of the sub-battery. | 0 to 1.27 Ohm | 0.005 to 0.5 Ohm | The sub-battery module measures its own internal resistance based on the correlation between the sub-battery current and sub-battery voltage. |
| Protection Relay FET Temperature1 | This parameter indicates the temperature of the Protection Relay FET1. | -50 to 120°C (-58 to 248°F) | -30 to 105°C (-22 to 221°F) |
|
| Protection Relay FET Temperature2 | This parameter indicates the temperature of the Protection Relay FET2. | -50 to 120°C (-58 to 248°F) | -30 to 105°C (-22 to 221°F) |
|
| Auxiliary Battery Voltage | Sub-battery module assembly B (+B) terminal voltage | 0 to 65.535 V | 11 to 14 V: Idling | This is the voltage of the B (+B) terminal of the sub-battery module as measured by the sub-battery module. |
| Auxiliary Battery Voltage for Gear Lever Position Sensor | Sub-battery module assembly +BAT terminal voltage | 0 to 65.535 V |
|
This is the voltage of the +BAT terminal of the sub-battery module as measured by the sub-battery module. |
| Backup Relay Status | This parameter indicates the status of the backup relay. | ON/OFF | ON: Backup relay ON | - |
| Protection Relay Status | This parameter indicates the status of the protection relay. | ON/OFF | ON: Protection relay ON | - |
| Hybrid Powertrain Control Module | This parameter indicates the availability of Hybrid system. | Without/With | With |
|
| Stop and Start Control Module | This parameter indicates the availability of Stop and Start System. | Without/With | Without |
|
| Power Switch Status | This parameter indicates the status of the power switch. | ON/OFF | OFF | - |
| Engine Status | This parameter indicates the status of the Engine. | ON/OFF | ON: Engine running | - |
| Backup Relay Active Preparation Status | This parameter indicates the status of the backup relay active preparation. | ON/OFF | - |
|
| Sub Battery Module Control Status | This parameter indicates the status of the sub-battery module control. | ECU Sleep /Self Wake-up / ECU Sleep Transition / IG ON / Normal / Sub Battery Module Back-up / Abnormal | - |
|
| Power Generator Voltage Request Status | This parameter indicates the status of the power generator voltage request. | Power Generator Voltage Not Request / Power Generator Voltage Up / Internal Resistance Calculate Mode | - |
|
| Stop&Start of Engine State | Stop and start control status | IG / Run / Stopreq / Stop / Restart |
|
- |
| Charging Control Mode | This parameter indicates the charging control mode. | SOC Keep / Auxiliary Charge / Refresh Charge / Normal / High/Low Temperature / Abnormal / SOC Calculate / Normal | - | This is the charging control condition sent by the ECM via CAN communication. |
| Voltage Change Status | This parameter indicates the status of the voltage change. | ON/OFF | ON | - |
| BRin Duty | This parameter indicates BRin input duty value. | 0 to 100% | 20 or 40% |
|
| BURDIAG1 Duty | This parameter indicates BURDIAG1 input duty value. | 0 to 100% | 40 or 60 or 80% |
|
| BURDIAG2 Duty | This parameter indicates BURDIAG2 input duty value. | 0 to 100% | 90% |
|
| ROout Duty | This parameter indicates ROout output duty value. | 0 to 100% | 20 or 40 or 60% | This is the duty ratio of the PWM signal* output from the RO (ROout) terminal of the sub-battery module. |
| BUR Duty | This parameter indicates BUR output duty value. | 0 to 100% | 60 or 80% |
|
| Protection Relay Open | This parameter indicates the number of times the protection relay has been changed from closed to open. | 0 to 1048575 | - | - |
| Protection Relay Close | This parameter indicates the number of times the protection relay has been changed from open to closed. | 0 to 1048575 | - | - |
| Backup Relay Open | This parameter indicates the number of times the backup relay has been changed from closed to open. | 0 to 1048575 | - | - |
| Backup Relay Close | This parameter indicates the number of times the backup relay has been changed from open to closed. | 0 to 1048575 | - | - |
| Protection Relay Overheat | This parameter indicates the number of times "Protection Relay Overheat" has been confirmed. | 0 to 65535 | - | - |
| Protection Relay Overcurrent | This parameter indicates the number of times "Protection Relay Overcurrent" has been confirmed. | 0 to 65535 | - | The number of times that the protection relay was opened to shut off overcurrent to protect the sub battery from damage. |
| Backup Relay Overheat | This parameter indicates the number of times "Backup Relay Overheat" has been confirmed. | 0 to 65535 | - | - |
| Backup Relay Overcurrent | This parameter indicates the number of times "Backup Relay Overcurrent" has been confirmed. | 0 to 65535 | - | - |
*: PWM communication (Pulse Width Modulation: Modulates pulse width according to duty ratio)
Active Test
Using the GTS to perform Active Tests allows relays to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Sub Battery Module / Active Test.
According to the display on the GTS perform the appropriate Active Test.
| Tester Display | Measurement Item | Diagnostic Note |
|---|---|---|
| Protection Relay | Turn protection relay on and off | IG ON |
| Backup Relay | Turn backup relay on and off | IG ON |