| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 8 (+) - 1 (E) | Switch pushed | Below 1 Ω |
| Switch not pushed | 10 kΩ or higher |
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 10 (ILL+) Battery negative (-) → 6 (ILL-) |
Illuminates |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (+B) - 4 (E) | Switch pushed | Below 1 Ω |
| Switch not pushed | 10 kΩ or higher |
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 2 (ILL+) Battery negative (-) → 5 (ILL-) |
Illuminates |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BM1) - 5 (+BM1) | Voltage is not applied between terminals 1 (MR1) and 2 (R1-) | 10 kΩ or higher |
| 3 (BM1) - 5 (+BM1) | Voltage is applied between terminals 1 (MR1) and 2 (R1-) | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (BM2) - 5 (+BM2) | Voltage is not applied between terminals 1 (MR2) and 2 (R2-) | 10 kΩ or higher |
| 3 (BM2) - 5 (+BM2) | Voltage is applied between terminals 1 (MR2) and 2 (R2-) | Below 1 Ω |