RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT H-LP LH RELAY

    B006XHCN01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the H-LP LH relay.

  2. INSPECT H-LP RH RELAY

    B006XHCN01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the H-LP RH relay.

  3. INSPECT FOG FR RELAY (w/ Front Fog Light)

    B006XHCN01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the FOG FR relay.

  4. INSPECT DIM RELAY (w/o Automatic Headlight Beam Level Control System)

    B006XHCN01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the DIM relay.

  5. INSPECT DRL RELAY (w/o Automatic Headlight Beam Level Control System)

    B006XHCN01

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the DRL relay.