WIPER AND WASHER SYSTEM Washer Fluid Level Warning Switch Circuit

DESCRIPTION

When the washer fluid level is lower than a certain level, a warning message is displayed on the combination meter assembly.

WIRING DIAGRAM

B00701ME02

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Combination Meter / Data List.

    5. Read the Data List according to the display on the GTS.


      Body Electrical > Combination Meter > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Washer Level Warning Switch Washer fluid level warning switch OFF or ON

      OFF: Washer fluid level not low

      ON: Washer fluid level low

      -

      Body Electrical > Combination Meter > Data List
      Tester Display
      Washer Level Warning Switch
      OK
      The GTS display changes correctly in response to the washer fluid level.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  2. INSPECT LEVEL WARNING SWITCH ASSEMBLY


    1. Remove the level warning switch assembly.

      Click here

    2. Inspect the level warning switch assembly.

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (LEVEL WARNING SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY)


    1. Disconnect the K21 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A3-1 (S) - K21-17 (WLVL) Always Below 1 Ω
      A3-1 (S) or K21-17 (WLVL) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (LEVEL WARNING SWITCH ASSEMBLY - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A3-2 (E) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG