AIR CONDITIONING PRESSURE SENSOR ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT AIR CONDITIONER PRESSURE SENSOR


    1. Check the wire harness.


      1. Disconnect the A18 air conditioner pressure sensor connector.

      2. Disconnect the K55 air conditioning amplifier assembly connector.

      3. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        A18-1 (-) - K55-3 (SG-4) Always Below 1 Ω
        A18-2 (PR) - K55-24 (PRE) Always Below 1 Ω
        A18-3 (+) - K55-6 (S5-3) Always Below 1 Ω
        A18-1 (-) or K55-3 (SG-4) - Other terminals and body ground Always 10 kΩ or higher
        A18-2 (PR) or K55-24 (PRE) - Other terminals and body ground Always 10 kΩ or higher
        A18-3 (+) or K55-6 (S5-3) - Other terminals and body ground Always 10 kΩ or higher

        If the resistance is not as specified, repair or replace the wire harness.

      4. Connect the K55 air conditioning amplifier assembly connector.

      5. Turn the ignition switch to ON.

      6. Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        A18-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V

        If the voltage is not as specified, repair or replace the wire harness or replace air conditioning amplifier assembly.

    2. Check the air conditioner pressure sensor.


      1. Connect the A18 air conditioner pressure sensor connector.

      2. Install a manifold gauge set.

      3. Turn the A/C switch on.

      4. B006YDNC32
        *a

        Component with harness connected

        (Air Conditioning Amplifier Assembly)

        Measure the voltage according to the value(s) in the table below.

        Tech Tips

        Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.

        Standard Voltage
        Tester Connection Condition Specified Condition
        K55-24 (PRE) - K55-3 (SG-4)

        Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi))

        0.74 to 4.61 V

        If the voltage is not as specified, replace the air conditioner pressure sensor.