ROOM TEMPERATURE SENSOR INSPECTION

PROCEDURE


  1. INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR


    1. B004MENC01
      *a

      Component without harness connected

      (Cooler (Room Temp. Sensor) Thermistor)

      *b Sensing Portion
      *c Resistance (kΩ)
      *d Temperature (°C (°F))
      *e Allowable Range

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      15°C (59°F) 2.45 to 2.88 kΩ
      20°C (68°F) 1.95 to 2.30 kΩ
      25°C (77°F) 1.60 to 1.80 kΩ
      30°C (86°F) 1.28 to 1.47 kΩ
      35°C (95°F) 1.00 to 1.22 kΩ
      40°C (104°F) 0.80 to 1.00 kΩ
      45°C (113°F) 0.65 to 0.85 kΩ
      50°C (122°F) 0.50 to 0.70 kΩ
      55°C (131°F) 0.44 to 0.60 kΩ
      60°C (140°F) 0.36 to 0.50 kΩ

      Note


      • Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).

      If the result is not as specified, replace the cooler (room temp. sensor) thermistor.