CONDENSER REASSEMBLY

PROCEDURE


  1. INSTALL COOLER DRYER


    1. B004IFAC01
      *a Modulator

      Using pliers, install a new cooler dryer to the modulator.

    2. B004KKZ

      Sufficiently apply compressor oil to 3 O-rings and the fitting surfaces of a new cap.

      Compressor Oil
      ND-OIL 8 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free from dirt or foreign matter.

    3. B004KXHC01
      *a Modulator

      Using a 14 mm straight hexagon, install the cap to the modulator.

      Torque:
      4.0 N*m  { 41 kgf*cm, 35 in.*lbf }