COMPRESSOR(for A25A-FKS) REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. REMOVE V-RIBBED BELT

    Click here

  3. REMOVE COOL AIR INTAKE DUCT SEAL

    Click here

  4. REMOVE INLET AIR CLEANER ASSEMBLY

    Click here

  5. DISCONNECT NO. 5 WATER BY-PASS HOSE

    Click here

  6. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE SUB-ASSEMBLY


    1. B0070IJ

      Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the No. 1 cooler refrigerant discharge hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.

  7. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    1. B006Y4U

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.

  8. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY


    1. B006YQC

      Disconnect the connector.

    2. B006YGQ

      Disconnect the connector.

    3. for Type A:


      1. B0071QNC01
        B006Z38 Bolt
        B006ZY0 Nut

        Remove the 2 bolts and 2 nuts.

      2. B006XWB

        Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor assembly with pulley.

    4. for Type B:


      1. B006YA9

        Remove the 4 bolts and compressor assembly with pulley.