PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE V-RIBBED BELT
REMOVE COOL AIR INTAKE DUCT SEAL
REMOVE INLET AIR CLEANER ASSEMBLY
DISCONNECT NO. 5 WATER BY-PASS HOSE
DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose sub-assembly from the compressor assembly with pulley.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.
REMOVE COMPRESSOR ASSEMBLY WITH PULLEY
Disconnect the connector.
Disconnect the connector.
for Type A:
|
Bolt |
|
Nut |
Remove the 2 bolts and 2 nuts.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor assembly with pulley.
for Type B:
Remove the 4 bolts and compressor assembly with pulley.