PROCEDURE
INSTALL PIPING CLAMP (for Suction Hose Sub-assembly Side)
Remove the vinyl tape from the suction pipe sub-assembly and suction hose sub-assembly.
| *1 | Suction Hose Sub-assembly |
| *2 | Piping Clamp |
| *a | Groove |
Install a new piping clamp to the suction hose sub-assembly.
Securely engage the inside step of the piping clamp in the groove of the suction hose sub-assembly.
Do not open the piping clamp more than the diameter of the suction hose sub-assembly when installing it.
Do not install the piping clamp with the large diameter section facing the wrong direction.
Sufficiently apply compressor oil to 2 new O-rings and the fitting surfaces of the suction hose sub-assembly.
| Compressor Oil |
|---|
| ND-OIL 8 or equivalent |
Install the 2 O-rings to the suction hose sub-assembly.
Keep the O-rings and O-ring fitting surfaces free from dirt and foreign matter.
| *a | Large Diameter Section of Piping Clamp |
| *b | Alignment Mark |
Align the alignment marks and connect the suction pipe sub-assembly and suction hose sub-assembly.
Connect the parts by holding the tubes, not the piping clamp.
| *a | Large Diameter Section of Piping Clamp |
Securely insert the piping clamp to the point where the large diameter section of the piping clamp is covered by the suction pipe sub-assembly.
When inserting, make sure that a click sound is heard.
Check that the suction hose sub-assembly is securely connected by pulling it.
INSTALL PIPING CLAMP (for Air Conditioner Tube and Accessory Assembly Side)
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
WARM UP ENGINE
INSPECT FOR REFRIGERANT LEAK