DESCRIPTION
If recirculation/fresh mode changes unintentionally and without permission, the following causes are possible.
| Symptom | Factor |
|---|---|
|
|
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction
|
| Tester Display |
|---|
| Ambient Temp Sensor |
| OK |
|---|
| The value of the display does not change frequently. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO AMBIENT TEMPERATURE DISPLAY SYSTEM Click here |
| OK |
|
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F), Max.: 140°C (284°F) | 75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature. Tech Tips
|
| Tester Display |
|---|
| Coolant Temperature |
| OK |
|---|
| The value of the display does not change frequently. |
| Result | |||
|---|---|---|---|
|
| NG |
|
GO TO COOLING SYSTEM for 2AR-FE: Click here |
| OK |
|
CHECK REFRIGERANT PRESSURE
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.6 kPaG (gauge) Max.: 3294.3 kPaG (gauge) |
Actual refrigerant pressure displayed |
|
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle doors | Fully open |
| Temperature setting | MAX COLD |
| Blower speed | HI |
| A/C switch | On |
| Recirculation/fresh switch | RECIRCULATION |
| Interior temperature | 25 to 35°C (77 to 95°F) |
| Standard Pressure |
|---|
| Low pressure side |
| 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) |
| High pressure side |
| 1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi) |
Compare the values displayed in the Data List and on the manifold gauge.
| OK |
|---|
| The values displayed in the Data List and on the manifold gauge match. |
| Result | |||
|---|---|---|---|
|
| OK |
|
GO TO ON-VEHICLE INSPECTION (CHECK REFRIGERANT PRESSURE USING GAUGE) Click here |
| NG |
|
REPLACE AIR CONDITIONER PRESSURE SENSOR Click here |