DESCRIPTION
If the cooling effect of the air conditioning system is weak, the following factors may be the cause.
| Symptom | Factor |
|---|---|
|
|
PROCEDURE
PERFORM REFRIGERANT SHORTAGE CHECK
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
| Tester Display |
|---|
| Refrigerant Gas Volume Check |
Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.
| Item | Condition |
|---|---|
| A/C switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Blower speed | HI |
*: If the ambient temperature is not within the range shown, do not perform this check.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|---|
| "Refrigerant correct" is displayed on GTS. |
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR REFRIGERANT LEAK Click here |
| OK |
|
PERFORM ACTIVE TEST USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128 Max.: 383 |
for LHD:
for RHD: |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| OK |
|---|
| The No. 1 air conditioning radiator damper servo motor operates. |
| Result | |||
|---|---|---|---|
|
| OK |
|
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET Click here |
| NG |
|
GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR Click here |