DESCRIPTION
If none of the switch indicators on the air conditioning control assembly illuminate, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| A/C switch indicator does not illuminate |
|
PROCEDURE
CHECK MALFUNCTION STATUS
Check the malfunction status of switch indicators on the air conditioning control assembly.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO INITIALIZATION Click here |
| A |
|
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly circuit malfunction
|
| Tester Display |
|---|
| Ambient Temp Sensor |
| OK |
|---|
| The value displayed is 0°C (32°F) or higher. |
| Result | |||
|---|---|---|---|
|
| OK |
|
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET Click here |
| NG |
|
GO TO OTHER DIAGNOSIS PROCEDURE (Ambient Temperature Display System) Click here |