AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) DIAGNOSTIC TROUBLE CODE CHART

Air Conditioning System (for Manual Air Conditioning System)
DTC No. Detection Item DTC Detection Condition Link
B1412 Ambient Temperature Sensor Circuit Open or short in ambient temperature sensor circuit

Click here

B1413 Evaporator Temperature Circuit or Evaporator Fin Thermistor Open or short in evaporator temperature sensor circuit

Click here

B1423 Open in Pressure Sensor Circuit / Abnormal Refrigerant Pressure
  • Open or short in air conditioner pressure sensor circuit

  • Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more)

Click here

B1441 Air Mix Damper Control Servo Motor Circuit (Passenger Side) Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air mix)

Click here

B1442 Air Inlet Damper Control Servo Motor Circuit Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly

Click here

B1443 Air Outlet Damper Control Servo Motor Circuit Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (mode)

Click here

B1449 Air Outlet Damper Control Servo Motor Circuit (Rear) Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly

Click here

B1451 Compressor Solenoid Circuit Open or short in compressor solenoid circuit

Click here

B1497 Communication Malfunction (Bus Ic) Error or open in communication line

Click here

B14B2 Lost Communication with Front Panel LIN Lost communication with air conditioning control assembly

Click here

B14B8 Refrigerant Shortage

The following condition is detected in the normal operation refrigerant shortage check:

Amount of refrigerant is insufficient

Click here

B14BD Refrigerant Overabundance Filling Malfunction

All of the following conditions are met 2 times or more in the same trip:


  • The vehicle speed is 20 km/h or more

  • The amount of compressor oil is within the insufficient compressor oil range for 60 seconds or more

Click here

U0100 Lost Communication With ECM/PCM "A" No communication with ECM

Click here

U0131 Lost Communication With Power Steering Control Module No communication with power steering ECU (rack and pinion power steering gear assembly)

Click here

U0142 Lost Communication With Body Control Module "B" No communication with main body ECU (multiplex network body ECU)

Click here

U0151 Lost Communication With Restraints Control Module No communication with airbag sensor assembly

Click here

U0155 Lost Communication With Instrument Panel Cluster (IPC) Control Module No communication with combination meter assembly

Click here