AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) DATA LIST / ACTIVE TEST

Click here
Click here
Click here
  1. DATA LIST

    Note:

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    Tip:

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus:


      1. for Air Conditioner: Body Electrical / Air Conditioner / Data List.

      2. for Engine: Powertrain / Engine / Data List.

    5. Read the Data List according to the display on the GTS.


      1. Body Electrical > Air Conditioner > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Ambient Temp Sensor Thermistor assembly

        Min.: -23.30°C (-9.94°F)

        Max.: 65.95°C (150.71°F)

        Actual ambient temperature displayed

        Thermistor assembly circuit malfunction


        • When open circuit: -23.30°C (-9.94°F)

        • When short circuit: 65.95°C (150.71°F)

        Adjusted Ambient Temp Adjusted ambient temperature

        Min.: -30.80°C (-23.44°F)

        Max.: 50.80°C (123.44°F)

        - Air conditioning amplifier assembly malfunction
        Evaporator Fin Thermistor No. 1 cooler thermistor

        Min.: -29.70°C (-21.46°F)

        Max.: 59.55°C (139.19°F)

        Actual evaporator temperature displayed

        No. 1 cooler thermistor circuit malfunction


        • When open circuit: -29.70°C (-21.46°F)

        • When short circuit: 59.55°C (139.19°F)

        Evaporator Target Temp Evaporator target temperature

        Min.: -327.68°C (-557.82°F)

        Max.: 327.67°C (621.81°F)

        Evaporator target temperature displayed

        No. 1 cooler thermistor circuit malfunction


        • When open circuit: -327.68°C (-557.82°F)

        • When short circuit: 327.67°C (621.81°F)

        Engine Coolant Temp Engine coolant temperature sensor

        Min.: 1.30°C (34.34°F)

        Max.: 90.55°C (194.99°F)

        Actual engine coolant temperature displayed
        • SFI system malfunction

        • CAN communication system malfunction

        Blower Motor Speed Level Blower motor speed level

        Min.: 0

        Max.: 31

        Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower motor with fan sub-assembly circuit malfunction
        Regulator Pressure Sensor Air conditioner pressure sensor

        Min.: -456.6 kPaG (gauge)

        Max.: 3294.3 kPaG (gauge)

        Actual refrigerant pressure displayed
        • Refrigerant line (gas leak etc.)

        • Air conditioner pressure sensor circuit malfunction

        Regulator Control Current Solenoid valve control current

        Min.: 0 A

        Max.: 0.997 A

        Value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
        Air Outlet Servo Pulse (R) No. 2 air conditioning radiator damper servo sub-assembly target pulse

        Min.: 128

        Max.: 383


        • FACE: 260 (pulse)

        • B/L: 212 (pulse)

        • FOOT: 182 (pulse)

        • F/D: 223 (pulse)

        • SHUT: 158 (pulse)

        • D/F: 177 (pulse)

        No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
        Air Outlet Servo Actual Pls(R) No. 2 air conditioning radiator damper servo sub-assembly actual pulse

        Min.: 128

        Max.: 383


        • FACE: 260 (pulse)

        • B/L: 212 (pulse)

        • FOOT: 182 (pulse)

        • F/D: 223 (pulse)

        • SHUT: 158 (pulse)

        • D/F: 177 (pulse)

        No. 2 air conditioning radiator damper servo sub-assembly circuit malfunction
        Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse

        Min.: 128

        Max.: 383


        • for LHD:
        • MAX COLD: 257 (pulse)

        • MAX HOT: 165 (pulse)


        • for RHD:
        • MAX COLD: 255 (pulse)

        • MAX HOT: 347 (pulse)

        No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction
        Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse

        Min.: 128

        Max.: 383


        • for LHD:
        • MAX COLD: 257 (pulse)

        • MAX HOT: 165 (pulse)


        • for RHD:
        • MAX COLD: 255 (pulse)

        • MAX HOT: 347 (pulse)

        No. 1 air conditioning radiator damper servo sub-assembly (air mix) circuit malfunction
        Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse

        Min.: 128

        Max.: 383


        • FACE-R: 241 (pulse)

        • FACE: 256 (pulse)

        • FACE1: 256 (pulse)

        • FACE2: 256 (pulse)

        • B/L: 267 (pulse)

        • B/L2: 267 (pulse)

        • FOOT-R: 297 (pulse)

        • FOOT: 297 (pulse)

        • FOOT-D: 305 (pulse)

        • FOOT-0: 288 (pulse)

        • F/D: 320 (pulse)

        • DEF-FOOT: 339 (pulse)

        • DEF or SHUT: 348 (pulse)

        No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction
        Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse

        Min.: 128

        Max.: 383


        • FACE-R: 241 (pulse)

        • FACE: 256 (pulse)

        • FACE1: 256 (pulse)

        • FACE2: 256 (pulse)

        • B/L: 267 (pulse)

        • B/L2: 267 (pulse)

        • FOOT-R: 297 (pulse)

        • FOOT: 297 (pulse)

        • FOOT-D: 305 (pulse)

        • FOOT-0: 288 (pulse)

        • F/D: 320 (pulse)

        • DEF-FOOT: 339 (pulse)

        • DEF or SHUT: 348 (pulse)

        No. 1 air conditioning radiator damper servo sub-assembly (mode) circuit malfunction
        Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse

        Min.: 128

        Max.: 383


        • Recirculation: 256 (pulse)

        • Fresh: 220 (pulse)

        No. 1 blower damper servo sub-assembly circuit malfunction
        Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse

        Min.: 128

        Max.: 383


        • Recirculation: 256 (pulse)

        • Fresh: 220 (pulse)

        No. 1 blower damper servo sub-assembly circuit malfunction
        Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
        Fan speed increment control Fan speed increment control Slow, Normal or Fast Customized value displayed -
        Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed -
        A/C Cutoff Signal A/C control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
        Refrigerant Gas Type Refrigerant gas type R134a or R1234yf Refrigerant gas type displayed -
        Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
        Number of Trouble Codes Number of trouble codes

        Min.: 0

        Max.: 255

        Number of DTCs displayed -
        Refrigerant High Pressure History Refrigerant high pressure history

        Min.: 0

        Max.: 255

        Number of times refrigerant high pressure history stored displayed *


























      • *: Refer to the following procedure to clear the refrigerant high pressure history.

        Click here


      1. Powertrain > Engine > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Coolant Temperature Engine coolant temperature

        Min.: -40°C (-40°F)

        Max.: 140°C (284°F)

        75 to 100°C (167 to 212°F): After warming up

        This is the engine coolant temperature.

        Tip:
        • After warming up the engine, the engine coolant temperature will be 75 to 100°C (167 to 212°F).

        • After a long soak, the engine coolant temperature, intake air temperature and ambient air temperature will be approximately equal.

        • If the value is -40°C (-40°F), or higher than 135°C (275°F), the sensor circuit is open or shorted.

        • Check if the engine overheats if the value indicated is higher than 135°C (275°F).



  2. ACTIVE TEST

    Tip:

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Perform the Active Test according to the display on the GTS.


      1. Body Electrical > Air Conditioner > Active Test
        Tester Display Measurement Item Control Range Diagnostic Note
        Blower Motor Blower motor with fan sub-assembly

        Min.: 0

        Max.: 31

        -
        Defogger Relay (Rear) Rear window defogger OFF or ON -
        Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse

        Min.: 128

        Max.: 383


        • for LHD:
        • Operates between 165 to 257 pulses


        • for RHD:
        • Operates between 255 to 347 pulses

        Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse

        Min.: 128

        Max.: 383

        Operates between 241 to 348 pulses
        Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse

        Min.: 128

        Max.: 383

        Operates between 220 to 256 pulses
        A/O Servo Pulse(Rr D) No. 2 air conditioning radiator damper servo sub-assembly pulse

        Min.: 128

        Max.: 383

        Operates between 158 to 260 pulses