CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K55-2 (SG-2) - Body ground | W - Body ground | Ground for thermistor assembly | Always | Below 1 V |
| K55-3 (SG-4) - Body ground | L - Body ground | Ground for air conditioner pressure sensor | Always | Below 1 V |
| K55-6 (S5-3) - K55-3 (SG-4) | GR - L | Power supply for air conditioner pressure sensor | Ignition switch ON | 4.75 to 5.25 V |
| Ignition switch off | Below 1 V | |||
| K55-13 (TAM) - K55-2 (SG-2) | R - W | Thermistor assembly signal |
|
1.05 to 1.45 V |
|
0.64 to 0.87 V | |||
| K55-24 (PRE) - K55-3 (SG-4) | W - L | Air conditioner pressure sensor signal |
|
4.61 V or higher |
|
Below 0.74 V | |||
|
0.74 to 4.61 V | |||
| K54-1 (B) - K54-4 (GND) | LA-B - W-B | Power source (Back-up) | Always | 11 to 14 V |
| K54-2 (IG+) - K54-4 (GND) | LA-GR - W-B | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| K54-3 (SOL+) - K54-4 (GND) | R - W-B | Compressor solenoid operation signal |
|
Pulse generation (See waveform 1) |
| K54-4 (GND) - Body ground | W-B - Body ground | Ground for main power supply | Always | Below 1 V |
| K54-6 (BLW) - K54-4 (GND) | LG - W-B | Blower motor speed control signal |
|
Pulse generation (See waveform 2) |
| K54-11 (CANH) - K54-12 (CANL) | SB - W | CAN communication system | CAN communication is performed | Pulse generation |
| K54-14 (LIN1) - K54-4 (GND) | BE - W-B | LIN communication signal | Ignition switch ON | Pulse generation (See waveform 3) |
| z8-2 (1A) - Body ground | - | Ground for BUS IC | Always | Below 1 V |
| z8-3 (2A) - z8-2 (1A) | - | BUS IC control signal | Ignition switch ON | Pulse generation (See waveform 4) |
| z8-4 (3A) - z8-2 (1A) | - | Power supply for BUS IC | Ignition switch off | 11 to 14 V |
| z8-5 (4A) - Body ground | GR - Body ground | Ground for No. 1 cooler thermistor | Always | Below 1 V |
| z8-6 (5A) - z8-5 (4A) | GR - GR | No. 1 cooler thermistor signal |
|
1.7 to 2.1 V |
|
0.9 to 1.3 V |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | K54-3 (SOL+) - K54-4 (GND) |
| Tool Setting | 5 V/DIV., 500 μs./DIV. |
| Condition |
|
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | K54-6 (BLW) - K54-4 (GND) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition |
|
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | K54-14 (LIN1) - K54-4 (GND) |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |
Waveform 4:
| Item | Content |
|---|---|
| Terminal No. | z8-3 (2A) - z8-2 (1A) |
| Tool Setting | 2 V/DIV., 2 ms./DIV. |
| Condition | Ignition switch ON |
CHECK AIR CONDITIONING CONTROL ASSEMBLY
Tech Tips
Check from the rear of the connector while it is connected to the air conditioning control assembly.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| K26-2 (IG+) - K26-6 (GND) | GR - W-B | Power source (IG) | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| K26-6 (GND) - Body ground | W-B - Body ground | Ground for air conditioning control assembly | Always | Below 1 V |
| K26-9 (LIN1) - Body ground | LG - Body ground | LIN communication signal | Ignition switch ON | Pulse generation (See waveform) |
| K26-11 (ILL+) - Body ground | W - Body ground | Illumination signal | Light control switch in off position | Below 1 V |
| Light control switch in tail or head position | 11 to 14 V | |||
| K26-15 (ILL-) - Body ground | B - Body ground | Illumination signal | Always | Below 1 V |
Waveform:
| Item | Content |
|---|---|
| Terminal No. | K26-9 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON |