TRIP SWITCH INSPECTION

PROCEDURE


  1. INSPECT TRIP SWITCH


    1. B004JO6C05
      *a

      Component without harness connected

      (Trip Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (RV) - 1 (E) Light control rheostat up switch pressed Below 50 Ω
      Light control rheostat up switch not pressed 10 kΩ or higher
      4 (RV) - 1 (E) Light control rheostat down switch pressed 1.71 to 1.94 kΩ
      Light control rheostat down switch not pressed 10 kΩ or higher
      3 (A/B) - 1 (E) ODO/TRIP switch pressed Below 50 Ω
      ODO/TRIP switch not pressed 10 kΩ or higher

      If the result is not as specified, replace the trip switch.

    2. Apply battery voltage to the trip switch and check that it illuminates.

      OK
      Condition Specified Condition

      Battery positive (+) → Terminal 5 (ILL+)

      Battery negative (-) → Terminal 2 (ILL-)

      Illuminates

      If the result is not as specified, replace the trip switch.