CAUTION / NOTICE / HINT
Note
This procedure includes the installation of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.
PROCEDURE
INSTALL WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
Install a new gasket to the water inlet with thermostat sub-assembly.
Tech Tips
Be sure to clean the contact surfaces.
Using an 8 mm socket wrench, install the water inlet with thermostat sub-assembly with the 2 bolts.
Connect the No. 7 water by-pass hose to the water inlet with thermostat sub-assembly and slide the clip to secure it.
Connect the water inlet with thermostat sub-assembly connector.
CONNECT NO. 2 RADIATOR HOSE
INSTALL GENERATOR ASSEMBLY
ADD ENGINE COOLANT
INSPECT FOR COOLANT LEAK