CAUTION / NOTICE / HINT
PROCEDURE
INSPECT REAR ENGINE MOUNTING INSULATOR
Disengage the clamp to separate the vacuum hose.
Disconnect the vacuum hose.
Using a vacuum pump, apply vacuum of 80 kPa (600 mmHg, 23.6 in.Hg) and wait for 1 minute.
Check that there is no change in the needle movement of the vacuum pump gauge.
| OK |
|---|
| Vacuum pressure holds. |
Check that there is no fluid leakage caused by a break in the diaphragm.
Connect the vacuum hose.
Engage the clamp to install the vacuum hose.