SFI SYSTEM(w/ Canister Pump Module) Ignition Circuit

DESCRIPTION

A direct ignition system is used on this vehicle. The direct ignition system is a 1 cylinder ignition system which ignites one cylinder with one ignition coil. In the 1 cylinder ignition system, one spark plug is connected to the end of the secondary winding. High voltage is generated in the secondary winding and is applied directly to the spark plug. The spark of the spark plug passes from the center electrode to the ground electrode.

The ECM determines the ignition timing and transmits the ignition signals for each cylinder. Using the ignition signal, the ECM turns on and off the power transistor inside the igniter, which switches on and off a current to the primary coil. When the current to the primary coil is cut off, high voltage is generated in the secondary coil and this voltage is applied to the spark plugs to create sparks inside the cylinders.

WIRING DIAGRAM

B006ZZYE02

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following procedure.

Tech Tips

Perform a spark test before proceeding. If there is no spark for any cylinder, inspect this circuit.

Click here

PROCEDURE


  1. CHECK TERMINAL VOLTAGE (POWER SOURCE OF IGNITION COIL ASSEMBLY)

    B006YXWC01
    *a

    Front view of wire harness connector

    (to Ignition Coil Assembly)


    1. Disconnect the ignition coil assembly connectors.

    2. Turn the engine switch on (IG).

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      C2-1 (+B) - C2-3 (GND) Engine switch on (IG) 11 to 14 V
      C4-1 (+B) - C4-3 (GND) Engine switch on (IG) 11 to 14 V
      C8-1 (+B) - C8-3 (GND) Engine switch on (IG) 11 to 14 V
      C11-1 (+B) - C11-3 (GND) Engine switch on (IG) 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - ECM)


    1. Disconnect the ignition coil assembly connectors.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C2-2 (IGT1) - C57-49 (IGT1) Always Below 1 Ω
      C4-2 (IGT2) - C57-48 (IGT2) Always Below 1 Ω
      C8-2 (IGT3) - C57-47 (IGT3) Always Below 1 Ω
      C11-2 (IGT4) - C57-46 (IGT4) Always Below 1 Ω
      C2-2 (IGT1) or C57-49 (IGT1) - Body ground and other terminals Always 10 kΩ or higher
      C4-2 (IGT2) or C57-48 (IGT2) - Body ground and other terminals Always 10 kΩ or higher
      C8-2 (IGT3) or C57-47 (IGT3) - Body ground and other terminals Always 10 kΩ or higher
      C11-2 (IGT4) or C57-46 (IGT4) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG
  3. CHECK HARNESS AND CONNECTOR (IGNITION COIL ASSEMBLY - BODY GROUND)


    1. Disconnect the ignition coil assembly connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C2-3 (GND) - Body ground Always Below 1 Ω
      C4-3 (GND) - Body ground Always Below 1 Ω
      C8-3 (GND) - Body ground Always Below 1 Ω
      C11-3 (GND) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (IG2 NO. 1 RELAY - IGNITION COIL ASSEMBLY)


    1. Disconnect the IG2 NO. 1 relay from engine room relay block and junction block assembly.

    2. Disconnect the ignition coil assembly connectors.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 (IG2 NO. 1 relay) - C2-1 (+B) Always Below 1 Ω
      3 (IG2 NO. 1 relay) - C4-1 (+B) Always Below 1 Ω
      3 (IG2 NO. 1 relay) - C8-1 (+B) Always Below 1 Ω
      3 (IG2 NO. 1 relay) - C11-1 (+B) Always Below 1 Ω
      3 (IG2 NO. 1 relay) or C2-1 (+B) - Body ground and other terminals Always 10 kΩ or higher
      3 (IG2 NO. 1 relay) or C4-1 (+B) - Body ground and other terminals Always 10 kΩ or higher
      3 (IG2 NO. 1 relay) or C8-1 (+B) - Body ground and other terminals Always 10 kΩ or higher
      3 (IG2 NO. 1 relay) or C11-1 (+B) - Body ground and other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG