ECM INSTALLATION

PROCEDURE


  1. INSTALL NO. 2 ECM BRACKET


    1. Install the No. 2 ECM bracket to the ECM with the 2 screws.

      Torque:
      4.5 N*m  { 46 kgf*cm, 40 in.*lbf }
  2. INSTALL NO. 1 ECM BRACKET


    1. Install the No. 1 ECM bracket to the ECM with the 2 screws.

      Torque:
      4.5 N*m  { 46 kgf*cm, 40 in.*lbf }
  3. INSTALL ECM


    1. Install the ECM with the nut and 2 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }

      Note

      If the ECM has been struck or dropped, replace it.

    2. B006Z5O

      Connect the 2 ECM connectors and rotate the 2 levers to lock them.

      Note


      • When connecting the ECM connectors, make sure that the connecting parts of the ECM connectors are free of dirt, water and other foreign matter.

      • Be sure to securely connect the ECM connectors.

  4. INSTALL AIR CLEANER ASSEMBLY


    1. B006YN1C01
      *a Up
      *b 13 to 19 mm (0.512 to 0.748 in.)

      Engage the 3 pins to install the air cleaner assembly.

    2. Install the air cleaner hose assembly to the air cleaner assembly.

    3. Tighten the hose clamp in the position shown in the illustration.

    4. Engage the 3 wire harness clamps.

    5. Connect the mass air flow meter sub-assembly connector.

  5. INSTALL INLET AIR CLEANER ASSEMBLY

    Click here

  6. INSTALL COOL AIR INTAKE DUCT SEAL

    Click here

  7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Click here

  8. PERFORM INITIALIZATION

    Click here