A25A-FKS AIR CLEANER FILTER ELEMENT REMOVAL

PROCEDURE


  1. SEPARATE AIR CLEANER CAP SUB-ASSEMBLY


    1. B004NYQC01
      *a Air Cleaner Cap Clamp
      *b Guide

      Disengage the 2 air cleaner cap clamps.

    2. Disengage the 2 guides to separate the air cleaner cap sub-assembly from the air cleaner case sub-assembly.

  2. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


    1. B004MJ3

      Remove the air cleaner filter element sub-assembly from the air cleaner case sub-assembly.

      Note

      Do not allow foreign matter to enter the air cleaner cap sub-assembly and air cleaner case sub-assembly.

  3. INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Tech Tips

    This procedure is only performed when the air cleaner filter element sub-assembly will be reused.


    1. Check whether the air cleaner filter element sub-assembly is dirty or clogged.

    2. B004MZZC02
      *a Air Cleaner Filter Element Sub-assembly Intake Downstream Side (Air Cleaner Cap Sub-assembly Side)

      If the air cleaner filter element sub-assembly is dirty or has foreign matter adhered to it, clean the air cleaner filter element sub-assembly with compressed air.

      Note

      When cleaning the air cleaner filter element sub-assembly, blow the compressed air from the intake downstream side (from the air cleaner cap sub-assembly side).

      Tech Tips

      If the air cleaner filter element sub-assembly is still extremely dirty after cleaning it, replace the air cleaner filter element sub-assembly with a new one.