| Brake Hold Switch |
for LHD
| Tester Connection |
Condition |
Specified Condition |
| 8 (+B) - 16 (GND1) |
Switch pushed |
Below 1 Ω |
| 8 (+B) - 16 (GND1) |
Switch not pushed |
10 kΩ or higher |
|
for RHD
| Tester Connection |
Condition |
Specified Condition |
| 1 (+B) - 9 (GND1) |
Switch pushed |
Below 1 Ω |
| 1 (+B) - 9 (GND1) |
Switch not pushed |
10 kΩ or higher |
|