A25A-FKS BATTERY / CHARGING SERVICE DATA

Battery Standard specific gravity 1.25 or higher at 20°C (68°F)
Standard voltage 12.3 V or higher at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard amperage 10 A or more
Standard voltage 13.5 to 14.4 V
Charging circuit with load Standard amperage 30 A or more
Generator brush holder assembly
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)
Generator rotor assembly
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.8 to 2.2 Ω
Slip ring - Rotor Always 10 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)