| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 8.0 mm (0.315 in.) or more at 95°C (203°F) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Always | 10.6 to 14.2 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 22 to 28 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 22 to 28 Ω |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator cap sub-assembly | Standard pressure (for brand-new radiator cap sub-assembly) |
74 to 103 kPa (0.8 to 1.1 kgf/cm2, 10.7 to 14.9 psi) |
| Minimum pressure (for used radiator cap sub-assembly) |
59 kPa (0.6 kgf/cm2, 8.6 psi) |