AMBIENT LIGHT INSPECTION

PROCEDURE


  1. INSPECT NO.1 INTERIOR ILLUMINATION LIGHT ASSEMBLY LH (AMBIENT ILLUMINATION LIGHT ASSEMBLY LH)


    1. A01ODNDC04
      *a

      Component without harness connected

      (Ambient Illumination Light Assembly LH)

      Apply auxiliary battery voltage to the connector and check that the ambient illumination light LH comes on.

      OK
      Measurement Condition Condition Specified Condition

      Auxiliary battery positive (+) → 1 (+)

      Auxiliary battery negative (-) → 2 (-)

      Always Ambient illumination light LH comes on

      If the result is not as specified, replace the ambient illumination light assembly LH.

  2. INSPECT NO.1 INTERIOR ILLUMINATION LIGHT ASSEMBLY RH (AMBIENT ILLUMINATION LIGHT ASSEMBLY RH)


    1. A01ODNDC04
      *a

      Component without harness connected

      (Ambient Illumination Light Assembly RH)

      Apply auxiliary battery voltage to the connector and check that the ambient illumination light RH comes on.

      OK
      Measurement Condition Condition Specified Condition

      Auxiliary battery positive (+) → 1 (+)

      Auxiliary battery negative (-) → 2 (-)

      Always Ambient illumination light RH comes on

      If the result is not as specified, replace the ambient illumination light assembly RH.