DESCRIPTION
When the blind spot monitor main switch (warning canceling switch assembly) is turned on, a signal is sent to the blind spot monitor sensor LH and the blind spot monitor indicator on the blind spot monitor main switch (warning canceling switch assembly) illuminates.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Main Switch | State of the blind spot monitor main switch (warning canceling switch assembly) | OFF or ON | OFF: Blind spot monitor main switch (warning canceling switch assembly) off ON: Blind spot monitor main switch (warning canceling switch assembly) on |
- |
| Tester Display |
|---|
| Main Switch |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| A |
|
INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)
Remove the blind spot monitor main switch (warning canceling switch assembly).
| *a | Component without harness connected (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - AUXILIARY BATTERY)
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BLIND SPOT MONITOR SENSOR LH)
Disconnect the U47 blind spot monitor sensor LH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE BLIND SPOT MONITOR SENSOR LH Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |