| DTC Code | DTC Name |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
DESCRIPTION
A battery current sensor is installed to the positive (+) cable side of the HV battery and detects current flowing from the HV battery. The battery current sensor outputs voltage, which changes between 0 and 5 V according to the detected amperage, to the IB terminal of the battery voltage sensor. The battery voltage sensor sends signals to the hybrid vehicle control ECU assembly. The hybrid vehicle control ECU assembly determines the charging and discharging amount of the HV battery based on the received signals and calculates the SOC of the HV battery through the accumulated amperage.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit | Power source voltage of the battery current sensor is excessively low/high. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low | The battery current sensor output value is excessively low. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High | The battery current sensor output value is excessively high. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| DTC No. | Data List |
|---|---|
| P0ABF-123 | Batt Pack Current Val |
| P0AC1-123 | |
| P0AC2-123 |
WIRING DIAGRAM
| *a | Hybrid Battery Junction Block Assembly (Battery Current Sensor) |
| *b | Battery Voltage Sensor |
Refer to the wiring diagram for DTC P0AFC-123.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (IG) and wait for 10 seconds or more.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
| Result | ||||||
|---|---|---|---|---|---|---|
|
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for and record any HV system DTCs, INF codes and freeze frame data.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the power switch off.
Disconnect the GTS from the DLC3.
| B |
|
GO TO DTC CHART (P0AFC-123) Click here |
| A |
|
CHECK BATTERY VOLTAGE SENSOR (IGCT VOLTAGE)
| Result | |||
|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 5 HV battery carrier bracket.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Tech Tips
As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:
Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)
Fuse condition (before and after removing fuse(s)) (IGCT circuit)
Connection condition of connectors (IGCT circuit)
Wire harness condition (IGCT circuit)
Wire harness condition (GND circuit)
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the upper No. 5 HV battery carrier bracket.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY VOLTAGE SENSOR POWER SOURCE CIRCUIT) |
| OK |
|
CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - HV BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 hybrid battery cover sub-assembly.
Disconnect the HV battery high voltage connector from the hybrid battery junction block assembly.
Disconnect the z14 battery current sensor connector from the hybrid battery junction block assembly.
Disconnect the z13 battery voltage sensor connector.
| *a | Rear view of wire harness connector (to Battery Voltage Sensor) |
| *b | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the tables below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Tech Tips
Because the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery.
Reconnect the z13 battery voltage sensor connector.
Reconnect the z14 battery current sensor connector to the hybrid battery junction block assembly.
Reconnect the HV battery high voltage connector to the hybrid battery junction block assembly.
Install the upper No. 1 hybrid battery cover sub-assembly.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR HARNESS OR CONNECTOR (BATTERY CURRENT SENSOR) |
| OK |
|
CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 5 HV battery carrier bracket.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the upper No. 5 HV battery carrier bracket.
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE BATTERY VOLTAGE SENSOR Click here |
| OK |
|
CHECK BATTERY VOLTAGE SENSOR (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 5 HV battery carrier bracket.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
| *a | Component with harness connected (Battery Voltage Sensor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the upper No. 5 HV battery carrier bracket.
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE BATTERY VOLTAGE SENSOR Click here |
| NG |
|
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY Click here |