| Symptom | Suspected Area | Link |
|---|---|---|
| "Maintenance required for hybrid battery cooling parts at your dealer" is displayed on the multi-information display.*1 | 1. Make sure the air intake port is not blocked. | - |
| 2. Make sure there are no gaps between the connecting parts of the ducts. | - | |
| 3. Clean the filter of the No. 2 hybrid battery intake duct. Check for entry of foreign matter. |
||
| 4. Clear the DTCs to reset the learning values even if no DTCs are stored. | ||
| Abnormal sound is heard from the area around the No. 2 hybrid battery intake duct. | 1. Make sure the air intake port is not blocked. | - |
| 2. Make sure there are no gaps between the connecting parts of the ducts. | - | |
| 3. Clean the filter of the No. 2 hybrid battery intake duct. Check for entry of foreign matter. |
*1: If the battery cooling blower assembly malfunctions, DTC P0A82-123, P0A84-123 or P0A85-123 will be stored. If only "Maintenance required for hybrid battery cooling parts at your dealer" is displayed on the multi-information display, perform the inspection of the HV battery cooling system intake port, filter and duct.