| DTC Code | DTC Name |
|---|---|
| P0A1A-517 | Generator Control Module |
| P0A1A-809 | Generator Control Module |
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that a large current flowed in the inverter for the generator. The cause of this malfunction may be one of the following:
Internal inverter malfunction
Internal circuit malfunction in the inverter for the generator
Malfunction in ECU that controls the inverter
DESCRIPTION
For a description of the inverter.
If a circuit malfunction, overheating or an overcurrent of the generator inverter is detected, a signal is sent from the inverter with converter assembly to the MG ECU via the inverter fail signal line.
If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the hybrid vehicle control ECU assembly of the malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A1A-517 | Generator Control Module | Generator inverter fail signal detected (MG ECU malfunction): Overcurrent occurs in the generator inverter.* (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P0A1A-809 | Generator Control Module | Abnormal generator inverter current (overcurrent) detected (MG ECU malfunction) (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
*: The inverter with converter assembly may be suspected as a main cause of the malfunction.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Drive the vehicle for approximately 10 minutes mainly using the engine.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | |||
|---|---|---|---|
|
Note
If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, perform troubleshooting for this DTC.
Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnostic procedure.
Turn the power switch off.
| P0A7A-203 is also output. |
|
GO TO DTC CHART (P0A7A-203) Click here |
| P0A7A-203 is not output. |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
Tech Tips
If P0A7A-203 was not output in step 1 of this diagnostic procedure, check Table 1 below.
If P0A7A-203 was output in step 1 of this diagnostic procedure, diagnose that DTC first, then check Table 2 below.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Table 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Table 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A1A-517 or P0A1A-809 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| *A | for LHD | *B | for RHD |
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |