HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A08-264

DTC Code DTC Name
P0A08-264 DC / DC Converter Status Circuit

DESCRIPTION

The DC/DC converter converts the DC 230.4 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle's lighting, audio, and ECU systems. In addition, it charges the auxiliary battery.

A transistor bridge circuit initially converts DC 230.4 V into alternating current, and a transformer lowers the voltage. Then, it is rectified and smoothed (into direct current) and converted into DC 12 V. The DC/DC converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.

The hybrid vehicle control ECU assembly sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal condition of the 12 V charging system via the NODD signal line.

If the DC/DC converter malfunctions, the vehicle will become inoperative. Therefore, the hybrid vehicle control ECU assembly monitors the operation of the DC/DC converter and detects malfunctions.

B004E6SE17

This DTC is stored when the DC/DC converter circuit has a malfunction or its operation is prohibited by a fail-safe function, or the auxiliary battery voltage drops to 11 V or less with the power switch on (READY). A signal indicating an auxiliary battery malfunction is sent from the DC/DC converter to the hybrid vehicle control ECU assembly via the NODD signal line.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A08-264 DC / DC Converter Status Circuit

The DC/DC converter is malfunctioning (charging has stopped) and the auxiliary battery voltage drops to 11 V or less.

(1 trip detection logic)

The DC/DC converter is malfunctioning for 120 seconds and the inverter coolant water temperature is 70°C or lower.

(1 trip detection logic)


  • Wire harness or connector

  • Inverter cooling system

  • Hybrid vehicle transmission assembly

  • Inverter with converter assembly

  • Fuse (DC/DC, DCDC-S)

  • Inverter wire sub-assembly

  • Hybrid vehicle control ECU assembly

Does not come on

Master Warning Light:

Comes on

Related Data List
DTC No. ECU Data List
P0A08-264
  • +B

  • Inverter Coolant Water Temperature

  • Short Wave Highest Val

Tech Tips


  • When the NODD signal line is open, DC/DC converter control is prohibited and the auxiliary battery voltage will be approximately 12 V (or less).

  • Regarding NODD signal circuit, when the transistor of the hybrid vehicle control ECU assembly turns on, a signal is sent to the inverter to prohibit DC/DC converter control. Sends a malfunction signal to the hybrid vehicle control ECU assembly when the inverter side transistor is on.

WIRING DIAGRAM

B004FLTE09
B004FLTE10

Refer to the wiring diagram for DTC P0AA6-526.

Click here

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

Tech Tips


  • After repair, clear the DTCs, turn the power switch off and wait for 30 seconds or more and perform the following procedure to confirm that the auxiliary battery low voltage indicated by this DTC has been repaired.


    1. Wait for 2 minutes with the shift lever in P, the power switch on (READY) and the following conditions met, then confirm that Data List item "+B" is between 13.0 and 15.0 V.

      (If charging is not performed and the electrical load increases, +B voltage may not be steady and gradually drops.)


      1. Headlight switch is in the HI position.

      2. A/C blower fan switch is in the HI position.

      3. Window defogger switch is turned on.

  • By performing the following procedure, the DC/DC converter function can be checked.


    1. Connect the AC/DC 400 A probe to the positive auxiliary battery cable.


      1. Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing to the auxiliary battery becomes 10 A or less.

      2. Turn the power switch on (READY) and the headlight switch and A/C blower fan switch in the HI position, and the window defogger turned on.

      3. Confirm that the current drawn from the auxiliary battery is 0 A or lower and the auxiliary battery voltage is between 13.0 and 15.0 V.


  • This DTC may be also stored when a part other than the DC/DC converter is malfunctioning or depending on user operation.

Malfunction cases to store DTC P0A08-264
Related Part, Inspection Note Inspection Step
Fuse is blown (DCDC-S, DC/DC) - 2, 5
A signal line connector of the hybrid vehicle control ECU assembly or inverter is not connected securely - 3, 4

High-voltage insulation fault of the following (ground to body).

- Between the motor and inverter

- Between the generator and inverter

DTC P0A08-264 may be stored if the ground potential fluctuates due to a high-voltage insulation malfunction. 6, 20, 21, 26 to 29
Check low-voltage line from the inverter to the hybrid vehicle control ECU assembly Inspect the continuity and connection condition of the AMD and S lines. 7 to 11, 22, 23
NODD signal line
  • Check the NODD signal line from the inverter to the hybrid vehicle control ECU assembly.

  • Check the NODD signal circuit inside the hybrid vehicle control ECU assembly.

12, 24
The DC/DC converter is malfunctioning Inspect the DC/DC converter function. 13

DC/DC converter control is suspended due to overheating

(inverter water pump with motor assembly is malfunctioning, the coolant is not sufficient, a hose is clogged, etc.)

When the inverter is overheating, the DC/DC converter has a self-protection function that may suspend the DC/DC converter control and output a DTC.

The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.

14 to 17
Check areas that caused the blown fuse (DCDC-S) - 18, ,19, 25

  • If this vehicle is used to jump start another vehicle with a discharged battery, a fuse may blow due to overcurrent or the DC/DC converter self-protection may be activated. Also, if this vehicle is jump started by a vehicle with a 24 V battery, the same malfunction may occur and this DTC may be stored. (The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the power switch off.)


  • Confirm that high electrical load equipment such as a high-capacitance audio device or electric kettle is used on the vehicle. (A fuse of the auxiliary battery may be blown due to overcurrent.)


  • If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the power switch is turned off, it may be impossible to turn it on (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.


  • If the power switch turns off immediately after it is turned on (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.


      Powertrain > Hybrid Control > Trouble Codes
      Result
      Result Proceed to
      P0A08-264 only is output, or DTCs except the ones in the table below are also output. A
      Any of the following DTCs including pending DTCs are also output. B
      Relevant DTC
      P0A1B-547 Drive Motor "A" Control Module
      P0A40-549 Drive Motor "A" Position Sensor Circuit Range / Performance
      P0A78-548 Drive Motor "A" Inverter Performance
      P0A93-346 Inverter Cooling System Performance
      P0AA6-526, 613 Hybrid Battery Voltage System Isolation Fault
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE6-225 Hybrid Battery Precharge Contactor Control Circuit Low
      P0C73-776 Motor Electronics Coolant Pump "A" Control Performance
      P3004-131, 803 High Voltage Power Resource
      P314A-828 Inverter Coolant Pump Speed Signal
    5. Turn the power switch off.


    B
    A
  2. CHECK FUSE (DCDC-S)


    1. B004GWEC02
      *1 Fusible Link Block Assembly
      *2 DCDC-S Fuse

      Remove the DCDC-S fuse from the fusible link block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      DCDC-S fuse terminals Always Below 1 Ω
    3. Install the DCDC-S fuse.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU ASSEMBLY CONNECTOR)

    Result
    Proceed to
    OK
    NG

    1. Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU assembly connectors.

      Click here

      OK
      The connectors are connected securely and there are no contact pressure problems.
      B004GK9C01
      *A for LHD *B for RHD
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    Result
    Result Proceed to
    OK A
    NG (The connector is not connected securely.) B
    NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

      Click here

      B004FMZC01
      *A for LHD *B for RHD

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    B
    C
    A
  5. CHECK FUSE (DC/DC)


    1. B004GVOC02
      *1 No. 1 Engine Room Relay Block and No. 1 Junction Block Assembly
      *2 DC/DC Fuse

      Check the DC/DC fuse in the No. 1 engine room relay block and No. 1 junction block assembly for improper installation.

      OK
      The DC/DC fuse is installed securely.
    2. Remove the DC/DC fuse from the No. 1 engine room relay block and No. 1 junction block assembly.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      DC/DC fuse terminals Always Below 1 Ω
    4. Install the DC/DC fuse.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  6. CHECK CABLE AND WIRE HARNESS

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004EFUC01
      *A for LHD
      *B for RHD

      Remove the inverter cover from the inverter with converter assembly.

    3. B004GSFC02
      *A for LHD
      *B for RHD
      *1 Motor Cable
      *2 Generator Cable

      Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      r1-1 (U) - Body ground and shield ground Power switch off 1 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 1 MΩ or higher
      r1-3 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
      q3-1 (U) - Body ground and shield ground Power switch off 1 MΩ or higher
      q3-2 (V) - Body ground and shield ground Power switch off 1 MΩ or higher
      q3-3 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      q1-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
      q1-2 (V) - Body ground and shield ground Power switch off 1 MΩ or higher
      q1-3 (U) - Body ground and shield ground Power switch off 1 MΩ or higher
      r1-1 (W) - Body ground and shield ground Power switch off 1 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 1 MΩ or higher
      r1-3 (U) - Body ground and shield ground Power switch off 1 MΩ or higher

      Tech Tips

      Perform this inspection while the generator cable and motor cable are connected.

    4. Install the inverter cover to the inverter with converter assembly.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  7. CHECK AMD TERMINAL VOLTAGE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Connect the cable to the negative (-) auxiliary battery terminal.

    2. B004G36C03
      *A for LHD
      *B for RHD

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      1J-1 (AMD) - Body ground Power switch off Same as auxiliary battery voltage
    3. Disconnect the cable from the negative (-) auxiliary battery terminal.

      Result
      Proceed to
      OK (for LHD)
      OK (for RHD)
      NG

    OK (for RHD)
    NG
    OK (for LHD)
  8. CHECK AMD TERMINAL CONNECTION CONDITION

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004FR8

      Check that the bolts for the AMD terminal are tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.

      Torque
      T = 18.0 N*m {184 kgf*cm, 13ft.*lbf} (Inverter with converter assembly side)
      T = 10.5 N*m {107 kgf*cm, 8ft.*lbf} (Inverter bus-bar plate sub-assembly side)
      T = 10.5 N*m {107 kgf*cm, 8ft.*lbf} (No. 1 engine room relay block and No. 1 junction block assembly side)
      Result
      Result Proceed to
      There are no arc marks. The terminal is connected securely and there is no contact problem. A
      There are no arc marks. The terminal is not connected securely and there is a contact problem. B
      There are arc marks. - C

    B
    C
    A
  9. CHECK INVERTER BUS-BAR PLATE SUB-ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the inverter bus-bar plate sub-assembly from the AMD terminal (inverter with converter assembly side and engine room main wire side).

    3. B004G9AC03
      *1 Inverter Bus-bar Plate Sub-assembly

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A-1 (AMD) - A82-1 (AMD) Always Below 1 Ω
    4. Install the inverter bus-bar plate sub-assembly.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  10. CHECK ENGINE ROOM MAIN WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004E6YC02
      *A No. 1 engine room relay block and No. 1 junction block assembly side
      *B Inverter bus-bar plate sub-assembly side

      Remove the engine room main wire from the AMD terminal (inverter bus-bar plate sub-assembly side and No. 1 engine room relay block and No. 1 junction block assembly side).

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1J-1 (AMD) - A-1 (AMD) Always Below 1 Ω
    4. Install the engine room main wire.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DCDC-S FUSE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. B004FS8C05
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Condition Specified Condition
      A84-3 (S) - Body ground Always Same as auxiliary battery voltage
      for RHD
      Tester Connection Condition Specified Condition
      A27-3 (S) - Body ground Always Same as auxiliary battery voltage
    5. Disconnect the cable from the negative (-) auxiliary battery terminal.

    6. Reconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

      Result
      Proceed to
      OK
      NG

    NG
    OK
  12. CHECK HARNESS AND CONNECTOR (RESISTANCE VALUE OF NODD INSIDE HYBRID VEHICLE CONTROL ECU ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. B004FS8C06
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      A84-5 (NODD) - Body ground Power switch off 110 to 150 kΩ
      for RHD
      Tester Connection Condition Specified Condition
      A27-5 (NODD) - Body ground Power switch off 110 to 150 kΩ
    4. Reconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

      Result
      Proceed to
      OK
      NG

    NG
    OK
  13. CHECK DC/DC CONVERTER FUNCTION

    Tech Tips

    The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.


    1. Connect the AC/DC 400 A probe of the tester to the positive auxiliary battery line.

    2. Install the service plug grip.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. B004EBVC08
      *a Probe Direction
      *b Current Flowing to Auxiliary Battery

      Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing to the auxiliary battery becomes 10 A or less.

      Tech Tips

      If the power switch turns off immediately after it is turned on (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.

    5. B004EVXC08
      *a Probe Direction
      *b Current Flowing from Auxiliary Battery

      Measure the current flowing from the auxiliary battery with the power switch on (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.

      Standard Current
      Item Condition Specified Condition
      Current flowing from auxiliary battery

      Power switch on (READY)

      (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)

      0 A or less

      (no current from auxiliary battery)

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Condition Specified Condition
      A84-3 (S) - Body ground

      Power switch on (READY)

      (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)

      Same as auxiliary battery voltage
      for RHD
      Tester Connection Condition Specified Condition
      A27-3 (S) - Body ground

      Power switch on (READY)

      (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)

      Same as auxiliary battery voltage
    7. Turn the power switch off.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  14. CHECK QUANTITY OF HV COOLANT

    Result
    Result Proceed to
    No leaks are found and the HV coolant level in the inverter reserve tank assembly is above the low line. A
    No leaks are found and the HV coolant level in the inverter reserve tank assembly is below the low line. B
    HV coolant leaks are evident. C

    1. Check the HV coolant level in the inverter reserve tank.

    2. Check for HV coolant leaks.

      Result
      Result Proceed to
      No leaks are found and the HV coolant level in the inverter reserve tank assembly is above the low line. A
      No leaks are found and the HV coolant level in the inverter reserve tank assembly is below the low line. B
      HV coolant leaks are evident. C

      Tech Tips


      • After repairing the HV coolant leaks and adding coolant, perform the "Activate the (Inverter) Water Pump" Active Test (HV Active Test item) and the "Control the Electric Cooling Fan" Active Test (Engine Active Test item) and make sure that there are no malfunctions.

      • The inverter water pump assembly will not malfunction due to coolant leaks.


    B
    C
    A
  15. CHECK COOLANT HOSE

    Result
    Proceed to
    OK
    NG

    1. Check that the cooling system hoses are not kinked or clogged.

      OK
      The cooling system hoses are not kinked or clogged.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  16. PERFORM ACTIVE TEST USING GTS (CONTROL THE ELECTRIC COOLING FAN)

    Result
    Proceed to
    OK
    NG

    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

    4. Perform the "Control the Electric Cooling Fan" Active Test.


      Powertrain > Engine and ECT > Active Test
      Tester Display
      Control the Electric Cooling Fan
      OK
      The cooling fan rotates.
    5. Turn the power switch off.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  17. CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)


    1. Connect the GTS to the DLC3

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read the freeze frame data item Ambient Temperature using the GTS.


      Powertrain > Hybrid Control > Trouble Codes
    5. Check if the freeze frame data item Ambient Temperature is below the freezing temperature of the HV coolant.

      Result
      Result Proceed to
      Ambient Temperature value is above freezing temperature of the HV coolant. A
      Ambient Temperature value is below freezing temperature of the HV coolant. B

      Tech Tips


      • HV coolant (SLLC) with a 30% concentration freezes at -15°C (5°F) and HV coolant (SLLC) with a 50% concentration freezes at -35°C (-31°F).

      • If the HV coolant freezes in the inverter radiator or inverter water pump, the coolant temperature in the inverter with converter assembly rises because the HV coolant cannot circulate. As a result, a DTC may be stored.

      • A DTC is stored when the inverter water pump impeller cannot rotate due to freezing of the HV coolant.

      • If a DTC is stored due to freezing of the HV coolant, the problem cannot be reproduced. Judge whether freezing of the HV coolant occurred according to the freeze point of the HV coolant, HV coolant change history and ambient temperature when the DTC was stored.

    6. Turn the power switch off.


    A
    B
  18. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - DCDC-S FUSE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Disconnect the fusible link block assembly.

    4. B004EZNC02
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Fusible Link Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      A84-3 (S) or U60-1 - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      A27-3 (S) or U60-1 - Body ground and other terminals Power switch off 10 kΩ or higher
    5. Install the fusible link block assembly.

    6. Reconnect the A84*1 or A27*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

      Result
      Proceed to
      OK
      NG

    NG
    OK
  19. REPLACE FUSIBLE LINK BLOCK ASSEMBLY


    1. Replace the fusible link block assembly.

      Result
      Proceed to
      NEXT

    NEXT
  20. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004EFUC01
      *A for LHD
      *B for RHD

      Remove the inverter cover from the inverter with converter assembly.

    3. B004F15C02
      *A for LHD
      *B for RHD
      *1

      Generator Cable

      (Inverter with Converter Assembly Side)

      Disconnect the generator cable from the inverter with converter assembly.

    4. B004F9RC02
      *A for LHD
      *B for RHD
      *1 Shield Ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      r1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      r1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    5. Connect the generator cable.

    6. Install the inverter cover.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  21. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004EFUC01
      *A for LHD
      *B for RHD

      Remove the inverter cover from the inverter with converter assembly.

    3. B004GV9C02
      *A for LHD
      *B for RHD
      *1

      Motor Cable

      (Inverter with Converter Assembly Side)

      Disconnect the motor cable from the inverter with converter assembly.

    4. B004EUDC02
      *A for LHD
      *B for RHD
      *1 Shield Ground
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      q3-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      q3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      q3-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      q1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      q1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      q1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    5. Connect the motor cable.

    6. Install the inverter cover.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  22. CHECK AMD TERMINAL CONNECTION CONDITION

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B004GQG

      Check that the bolts for the AMD terminal are tightened to the specified torque, the AMD terminal is connected securely, and there is no contact problem.

      Torque
      T = 18.0 N*m {184 kgf*cm, 71 in.*lbf} (Inverter with converter assembly side)
      T = 10.5 N*m {177 kgf*cm, 8 in.*lbf} (No. 1 engine room relay block and No. 1 junction block assembly side)
      Result
      Result Proceed to
      There are no arc marks. The terminal is connected securely and there is no contact problem. A
      There are no arc marks. The terminal is not connected securely and there is a contact problem. B
      There are arc marks. - C

    B
    C
    A
  23. CHECK INVERTER BUS-BAR PLATE SUB-ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the inverter bus-bar plate sub-assembly from the AMD terminal (inverter with converter assembly side and No. 1 engine room relay block and No. 1 junction block assembly side).

    3. B004GDWC07
      *1 Inverter Bus-bar Plate Sub-assembly

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E1-1 (AMD) - 1J-1 (AMD) Always Below 1 Ω
    4. Install the inverter bus-bar plate sub-assembly.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  24. INSPECT HYBRID VEHICLE CONTROL ECU ASSEMBLY (RESISTANCE VALUE OF NODD INSIDE HYBRID VEHICLE CONTROL ECU ASSEMBLY)


    1. B004GIFC67
      *a

      Component without harness connected

      (Hybrid Vehicle Control ECU Assembly)

      Disconnect the A80, A81, O141 and O142 hybrid vehicle control ECU assembly connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A80-25 (NODD) - O141-6 (E1) Power switch off 110 to 150 kΩ
    3. Reconnect the A80, A81, O141 and O142 hybrid vehicle control ECU assembly connectors.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  25. REPAIR OR REPLACE HARNESS OR CONNECTOR

    Result
    Proceed to
    NEXT

    NEXT
  26. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    Result
    Result Proceed to
    The terminals are connected securely and there are no contact problems. There are no arc marks. A
    The terminals are not connected securely and there is a contact problem. There are arc marks. B
    The terminals are not connected securely and there is a contact problem. There are no arc marks. C
    The terminals are connected securely and there are no contact problems. There are arc marks. B

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid vehicle transmission assembly.

      Click here

    3. B004E1M

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the generator cable from the hybrid vehicle transmission assembly.

    5. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the hybrid vehicle transmission assembly.

    7. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  27. CHECK GENERATOR CABLE

    Result
    Result
    OK
    NG

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable.

      Click here

    3. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      r1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      r1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      r1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      B004FNWC03
      *A for LHD *B for RHD
      *1 Shield ground - -
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      *b

      Generator Cable

      (Hybrid Vehicle Transmission Assembly Side)

      Note

      Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      r1-3 (W) - r2-1 (U) Power switch off 100 MΩ or higher
      r1-2 (V) - r2-3 (W) Power switch off 100 MΩ or higher
      r1-1 (U) - r2-2 (V) Power switch off 100 MΩ or higher
      r1-3 (W) - r2-3 (W) Power switch off Below 1 Ω
      r1-2 (V) - r2-2 (V) Power switch off Below 1 Ω
      r1-1 (U) - r2-1 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      r1-1 (W) - r2-1 (U) Power switch off 100 MΩ or higher
      r1-2 (V) - r2-3 (W) Power switch off 100 MΩ or higher
      r1-3 (U) - r2-2 (V) Power switch off 100 MΩ or higher
      r1-1 (W) - r2-3 (W) Power switch off Below 1 Ω
      r1-2 (V) - r2-2 (V) Power switch off Below 1 Ω
      r1-3 (U) - r2-1 (U) Power switch off Below 1 Ω
    5. Install the generator cable.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  28. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    Result
    Result Proceed to
    The terminals are connected securely and there are no contact problems. There are no arc marks. A
    The terminals are not connected securely and there is a contact problem. There are arc marks. B
    The terminals are not connected securely and there is a contact problem. There are no arc marks. C
    The terminals are connected securely and there are no contact problems. There are arc marks. B

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid vehicle transmission assembly.

      Click here

    3. B004GIP

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the motor cable from the hybrid vehicle transmission assembly.

    5. Check for arc marks at the terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the motor cable to the hybrid vehicle transmission assembly.

    7. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  29. CHECK MOTOR CABLE

    Result
    Result
    OK
    NG

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the motor cable.

      Click here

    3. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      B004GWLC03
      *A for LHD *B for RHD
      *1 Shield ground - -
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      *b

      Motor Cable

      (Hybrid Vehicle Transmission Assembly Side)

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      q3-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      q3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      q3-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Condition Specified Condition
      q1-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      q1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      q1-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      q3-3 (W) - q2-3 (U) Power switch off 100 MΩ or higher
      q3-2 (V) - q2-1 (W) Power switch off 100 MΩ or higher
      q3-1 (U) - q2-2 (V) Power switch off 100 MΩ or higher
      q3-3 (W) - q2-1 (W) Power switch off Below 1 Ω
      q3-2 (V) - q2-2 (V) Power switch off Below 1 Ω
      q3-1 (U) - q2-3 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Condition Specified Condition
      q1-1 (W) - q2-3 (U) Power switch off 100 MΩ or higher
      q1-2 (V) - q2-1 (W) Power switch off 100 MΩ or higher
      q1-3 (U) - q2-2 (V) Power switch off 100 MΩ or higher
      q1-1 (W) - q2-1 (W) Power switch off Below 1 Ω
      q1-2 (V) - q2-2 (V) Power switch off Below 1 Ω
      q1-3 (U) - q2-3 (U) Power switch off Below 1 Ω
    5. Install the motor cable.

      Result
      Proceed to
      OK
      NG

    OK
    NG