CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Disconnect the O9 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
Tech Tips
Measure the values on the wire harness side with the connector disconnected.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O9-5 (IG+) - O9-1 (GND) | R - BR | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| O9-5 (IG+) - O9-1 (GND) | R - BR | Power source (IG) | Power switch off | Below 1 V |
| O9-6 (+B1) - O9-1 (GND) | L - BR | Auxiliary battery power supply | Power switch off | 11 to 14 V |
| O9-1 (GND) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
Reconnect the O9 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| O9-24 (FDEF) - O9-1 (GND) | G - BR | Wiper Deicer signal | Power switch on (IG), Front wiper deicer switch off | 11 to 14 V |
| O9-24 (FDEF) - O9-1 (GND) | G - BR | Wiper Deicer signal | Power switch on (IG), Front wiper deicer switch on | Below 2.2 V |
| O9-17 (SWL2) - O9-1 (GND) | R - BR | Front wiper deicer switch indicator signal | Power switch on (IG), Front wiper deicer switch off | 11 to 14 V |
| O9-17 (SWL2) - O9-1 (GND) | R - BR | Front wiper deicer switch indicator signal | Power switch on (IG), Front wiper deicer switch on | Below 1 V |
| O10-28 (SW6) - O9-1 (GND) | V - BR | Front wiper deicer switch signal | Power switch on (IG), Front wiper deicer switch off | 11 to 14 V |
| O10-28 (SW6) - O9-1 (GND) | V - BR | Front wiper deicer switch signal | Power switch on (IG), Front wiper deicer switch on | Below 1 V |