PROCEDURE
INSTALL SEMICONDUCTOR POWER INTEGRATION ECU
Connect the 5 connectors.
|
Install in this Direction |
Engage the 2 claws to install the semiconductor power integration ECU as shown in the illustration.
INSTALL NO. 1 RELAY BLOCK COVER
|
Install in this Direction (1) |
|
Install in this Direction (2) |
Engage the 2 guides and claw to install the No. 1 relay block cover as indicated by the arrows, in the order shown in the illustration.
|
Install in this Direction (1) |
|
Install in this Direction (2) |
Engage the 2 guides and claw to install the No. 1 relay block cover as indicated by the arrows, in the order shown in the illustration.
INSTALL RESERVOIR BRACKET (for LHD)
CONNECT BRAKE MASTER CYLINDER RESERVOIR ASSEMBLY (for LHD)
|
Bolt |
|
Connector |
|
Install in this Direction |
Move the brake master cylinder reservoir assembly as shown in the illustration to engage the 2 claws.
Connect the reservoir level switch connector and install the bolt.
CONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note