PANORAMIC VIEW MONITOR SWITCH INSPECTION

PROCEDURE


  1. INSPECT PANORAMIC VIEW MONITOR SWITCH (INTEGRATION CONTROL AND PANEL ASSEMBLY)


    1. Remove the panoramic view monitor switch (integration control and panel assembly).

      Click here

    2. A01RET6C05
      *a

      Component without harness connected

      (Panoramic View Monitor Switch (Integration Control and Panel Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      5 (D) - 17 (E) Panoramic view monitor switch pushed Below 50 Ω
      Panoramic view monitor switch not pushed 1 MΩ or higher

      If the result is not as specified, replace the panoramic view monitor switch (integration control and panel assembly).

    3. Check that the switch illumination illuminates.


      1. A01RET6C02
        *a

        Component without harness connected

        (Panoramic View Monitor Switch (Integration Control and Panel Assembly))

        Apply battery voltage to the panoramic view monitor main switch and check that the switch illumination illuminates.

        OK
        Connection Specified Condition

        Battery positive (+) → Terminal 8 (ILL+)

        Battery negative (-) → Terminal 15 (ILL-)

        Illuminates

        If the result is not as specified, replace the panoramic view monitor switch (integration control and panel assembly).

    4. Install the panoramic view monitor switch (integration control and panel assembly).

      Click here