PROCEDURE
INSTALL COOLER DRYER
| *a | Modulator |
Using pliers, install a new cooler dryer to the modulator.
Sufficiently apply compressor oil to the 3 O-rings and the fitting surface of a new cap.
| Refrigerant | Compressor Oil |
|---|---|
| HFC-134a (R134a) | ND-OIL 8 or equivalent |
| HFO-1234yf (R1234yf) | ND-OIL 12 or equivalent |
Note
Keep the O-rings and O-ring fitting surfaces free from dirt or foreign matter.
| *a | Modulator |
Using a 14 mm straight hexagon socket wrench, install the cap to the modulator.